Evidence map›Paper›PMID 33650504›Full record

ArticleActa orthopaedica et traumatologica turcica2021

Interfragmentary lag screw and locking plate combination in simple distal femoral fractures: A finite element analysis.

Jun Zhang, Yan Wei, Guoding Li, Jian Wang, Youjia Xu

Abstract read
In one paragraph

Article in Acta orthopaedica et traumatologica turcica, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jun ZhangDepartment of Orthopaedics, The Second Affiliated Hospital of Soochow University, Suzhou, China;Department of Orthopaedics, Pudong New Area People's Hospital affiliated to Shanghai University of Medicine - Health Sciences, Shanghai, China.
Yan WeiDepartment of Surgery, Pudong New Area People's Hospital affiliated to Shanghai University of Medicine - Health Sciences, Shanghai, China.
Guoding LiDepartment of Orthopaedics, Pudong New Area People's Hospital affiliated to Shanghai University of Medicine - Health Sciences, Shanghai, China.
Jian WangDepartment of Orthopaedics, Pudong New Area People's Hospital affiliated to Shanghai University of Medicine - Health Sciences, Shanghai, China.
Youjia XuDepartment of Orthopaedics, The Second Affiliated Hospital of Soochow University, Suzhou, China.

Funding

HSRD VA CDP 13-003
6 · The paper itself

Abstract

objectiveThe aim of this study was to evaluate the strength of the locking plate and lag screw construct that is applied in two different working lengths on the simple distal femur fracture model with a finite element analysis (FEA) method.

methodsFrom the computerized tomography scan data of a 60-year-old healthy male, the AO/OTA 33A1-type fracture model was simulated; the fracture gap was stabilized with the models of locking plate construct with (groups C and D) or without an interfragmentary lag screw (groups A and B). Furthermore, 102-mm plate (groups A and C) and 82-mm plate working lengths (groups B and D) were tested using FEA. Two loading conditions (axial compression and torsion) were applied at the center of the femoral head. Construct stiffness, interfragmentary micromotion, and the peak von Mises stress (VMS) on the plate were assessed.

resultsGroup D provided the highest axial stiffness (1347 N/mm), and group A was the weakest (439 N/mm). With the lag screw, shear micromotion remained generally low compared with that without the screw for all axial and torsional load levels and for both plate working lengths, i.e., 0.23 mm with lag screw versus 0.43 mm without lag screw (102 mm working length, 700 N). The percentage decreases of shear micromotion under axial (350/700/1400 N) and torsional loads for the 102-mm working length were >22% and 73%, respectively; while those for the 82-mm working length were >28% and 33%, respectively. The reduction of axial micromotion was observed with the lag screw for all axial load levels as well as for both plate working lengths, i.e., 0.33 mm with lag screw versus 0.87 mm without lag screw (102-mm working length, 700 N). The percentage decreases of axial micromotion under axial loading (350/700/1400 N) for 102 mm and 82 mm working lengths were >42% and 50%, respectively. The peak VMS on the plate stayed generally low with lag screw compared with without lag screw throughout all tested load levels, as well as for both plate working lengths, i.e., 124.26 MPa versus 244.39 MPa (102 mm working length, 700 N). The percentage decreases of the peak VMS under axial (350/700/1400 N) and torsional loads for the 102-mm working length were >40% and 69%, respectively, while those for the 82-mm working length were >47% and 61%, respectively.

conclusionThe current FEA concludes that in a simple distal femur fracture, adding a lag screw to a locking plate construct provides better torsional stability with a 102-mm plate working length and better axial stability with a 82-mm plate working length. Additionally, the strength of the materials is increased and implant failure can be minimized by using this technique.

Indexed as

Fracture Fixation, InternalBiomechanical PhenomenaBone PlatesBone ScrewsComputer SimulationFemoral FracturesFinite Element AnalysisHumansMaleMiddle AgedModels, Anatomic

Identifiers

PMID33650504
PMCPMC7932744

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked