Evidence map›Paper›PMID 33649710›Full record

ArticleBuilding simulation2021

Gaseous pollutant transport from an underground parking garage in a Mediterranean multi-story building-Effect of temporal resolution under varying weather conditions.

Rivka Reichman, Yael Dubowski

Abstract read
In one paragraph

Article in Building simulation, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Rivka ReichmanFaculty of Civil and Environmental Engineering, Technion - Israel Institute of Technology, Haifa, 32000 Israel.
Yael DubowskiFaculty of Civil and Environmental Engineering, Technion - Israel Institute of Technology, Haifa, 32000 Israel.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Indoor air dynamics and quality in high density residential buildings can be complex as it is affected by both building parameters, pollution sources, and outdoor meteorological conditions. The present study used CONTAM simulations to investigate the intra-building transport and concentration of an inert pollutant continuously emitted from an underground garage of a 15-floor building under moderate Mediterranean weather. The effects of outdoor meteorological conditions (air temperature, wind speed and direction) on indoor distribution of the emitted pollutant was tested under constant conditions. The importance of using actual transient meteorological data and the impact of their temporal resolution on calculated concentrations and exposure levels were also investigated. Vertical profiles of air exchange rate (AER) and CO concentration were shown to be sensitive to indoor-outdoor temperature difference, which controls the extent of the stack effect and its importance relative to wind effect. Even under constant conditions, transient mode simulations revealed that the time needed for pollutant distribution to reach steady state can be quite long (>24h in some cases). The temporal resolution (1h vs. 8h) of the meteorological data input was also found to impact calculated exposure levels, in an extent that varied with time, meteorological conditions and apartment position.

Indexed as

CONTAMhigh rise residential buildingsindoor air qualityinter-flat dispersionstack effectvariable meteorological data effectwind effect

Identifiers

PMID33649710
PMCPMC7905197

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.