Evidence map›Paper›PMID 33647100›Full record

ArticleAmerican journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists2021

NCPDP recommendations for standardizing dosing in metric units (mL) on prescription container labels of oral liquid medications, version 2.0.

Abstract read
In one paragraph

Article in American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Evaluation of Measuring Devices Packaged With Prescription Oral Liquid Medications.The journal of pediatric pharmacology and therapeutics : JPPT : the official journal of PPAG
    Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

0 authors.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeBest practices and guidance are provided for standardizing dosing instructions on prescription container labels of oral liquid medications by eliminating use of U.S. customary (household) units and adopting metric units universally, with the goal of decreasing the potential for error and improving safety and outcomes when patients and caregivers take and administer these medications. SUMMARY: Despite decades of best practice use of metric units in organized healthcare settings and advocacy by various professional societies, medication safety experts, and standards setting organizations, use of household units (e.g., teaspoon) on prescription container labeling instructions for oral liquid medications persists in community pharmacy settings. Five years after publication of the National Council for Prescription Drug Programs' (NCPDP's) original white paper advocating metric-only dosing, very few community pharmacy companies appear to require oral liquid dosing instructions be presented in metric-only units (mL). Error-prone dosing designations contribute to medication errors and patient harm. Use of both multiple volumetric units (e.g., teaspoonsful, tablespoonsful) and multiple abbreviations for the same volumetric units (e.g., mL, cc, mls; tsp, TSP, t) increases the likelihood of dosing errors. Opportunities for error exist with each administration of an oral liquid medication and, unless coordinated with dispensing of appropriate oral dosing devices and optimal counseling, can result in use of household utensils (e.g., uncalibrated teaspoons) or discordantly marked devices that can further exacerbate the risk of error. Since publication of NCPDP's original white paper, new standards have been adopted governing official liquid volume representation, calibrated dosing devices, and e-prescribing software which support the elimination of non-metric units to reduce use of dosing practices that are error-prone. In each case, U.S. customary (household) units have been eliminated in official standards and certification requirements. Therefore, use of non-metric units for oral dosing of liquid medications no longer is an acceptable practice.

conclusionKey factors contributing to dosing errors with oral liquid medications include use of multiple volumetric units and abbreviations; failure to institute policies and procedures that eliminate the use of non-metric (e.g., household) units and universally adopt metric-only dosing instructions in all settings; failure to coordinate dosing instructions with dosing device markings, appropriate type (oral syringe versus cup), and optimal volumes (e.g., 1-, 5-, or 10-mL devices); failure to adequately counsel patients about appropriate measurement and administration of oral liquid medication doses; and use or error-prone practices such as missing leading zeros and elimination of trailing zeros in prescriptions and container labels. Adoption of this white paper's recommendations will align dosing designations for oral liquid medications in all settings with current standards and attain universal metric-only practice.

Indexed as

Electronic PrescribingPrescription DrugsAdministration, OralDelivery of Health CareHumansMedication ErrorsPrescription DrugsAdministrationComprehensionDrug Labeling/StandardsElectronic PrescribingMedication Errors/Prevention & ControlOralParentsPediatriciansPharmaceutical Solutions/Administration & DosagePharmacistsPhysiciansPractice Guidelines as TopicPrimary CareSyringes/StandardsWeights and Measures

Identifiers

PMID33647100
PMCPMC7970405

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.