ArticlePloS one2021
Rotational stability of modified toric intraocular lens.
Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed.
- Reproducibility of the Magnitude of Lens Rotation Following Implantation of a Toric Intraocular Lens with Modified Haptics.Clinical ophthalmology (Auckland, N.Z.) · 2022Trial
- Misalignment After Implantation of One-Piece Hydrophobic Toric Intraocular Lenses: Comparison Among Manufacturers and Generations.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
- Comparative effectiveness of toric IOLs and LRIs for correction of moderate regular astigmatism during phacoemulsification.Scientific reports · 2025Article
- Clinical impact of intraocular lens tilt and decentration: a cross-sectional study.BMC ophthalmology · 2025Article
- Postoperative Rotation and Refractive Efficacy of Toric Intraocular Lenses After Phacoemulsification Cataract Surgery.Ophthalmology and therapy · 2025Article
- Study on Factors Affecting Toric Intraocular Lens Rotation Using Intraoperative OCT-Factors Influencing IOL Deployment and Proximity to Posterior Capsule After Insertion.Journal of clinical medicine · 2025Article
- Clinical Outcomes Following Toric Intraocular Lens Implantation: A Case Series Study.Journal of clinical medicine · 2025Article
- Comparing Rotational Stability of Clareon and Eyhance Toric IOLs in a Real-World Setting.Clinical ophthalmology (Auckland, N.Z.) · 2025Article
- Surgical approaches to correct corneal astigmatism at time of cataract surgery: a mini-review.International journal of ophthalmology · 2024Review
- Influence of decentration of plate-haptic toric intraocular lens on postoperative visual quality.BMC ophthalmology · 2023Article
- Biomedical Silicones: Leveraging Additive Strategies to Propel Modern Utility.ACS macro letters · 2023Article
- Long-term outcomes of cataract surgery with toric intraocular lens implantation by the type of preoperative astigmatism.Scientific reports · 2022Article
- Influence of frosted haptics on rotational stability of toric intraocular lenses.Scientific reports · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We evaluated the rotational stability of a new toric intraocular lens (IOL), HOYA XY-1 toric IOL that is an improved version of HOYA 355 toric IOL, with longer overall length (13.0 mm vs. 12.5 mm), shortened unfolding time, and texture processing of the surface of haptics. Data from 193 eyes of 165 patients (76.4 ± 8.3 years old) with preoperative corneal astigmatism exceeding 0.75 diopters who had undergone phacoemulsification and toric IOL implantation were collected and analyzed. Corneal astigmatism, refractive astigmatism, and uncorrected (UDVA) and corrected distance visual acuity (CDVA) were evaluated before and 1 day, 1 week, and 1 month after surgery. The degree of IOL decentration, IOL tilt, and toric axis misalignment was assessed at 1 day and 1 month postoperatively. Fifty eyes received AcrySof toric IOL, 51 eyes TECNIS toric IOL, 46 eyes HOYA 355 toric IOL, and 46 eyes HOYA XY-1 toric IOL. The amount of axis misalignment from the intended axis was significantly different among IOLs (p = 0.004, one-way ANOVA), and HOYA XY-1 showed significantly less amount of axis misalignment than TECNIS (p = 0.020, Tukey's multiple comparison) and HOYA 355 (p = 0.010). The proportion of eyes that showed axis misalignment <10° at 1 month postoperatively was significantly higher with HOYA XY-1 toric IOL than with other toric IOLs (χ2 test, p = 0.020). HOYA XY-1 toric IOL, the modified version of HOYA 355 toric IOL, showed excellent rotational stability in comparison with other models of toric IOLs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.