Evidence map›Paper›PMID 33644263›Full record

ArticleEuropean journal of radiology open2021

Impact of different phased-array coils on the quality of prostate magnetic resonance images.

Daniel Stocker, Andrei Manoliu, Anton S Becker, Borna K Barth, Daniel Nanz, Markus Klarhöfer, Olivio F Donati

Open access · goldAbstract read
In one paragraph

Article in European journal of radiology open, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Daniel StockerInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich and University of Zurich, Switzerland.
Andrei ManoliuInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich and University of Zurich, Switzerland.
Anton S BeckerInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich and University of Zurich, Switzerland.
Borna K BarthInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich and University of Zurich, Switzerland.
Daniel NanzInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich and University of Zurich, Switzerland.
Markus KlarhöferSiemens Healthcare AG, Zurich, Switzerland.
Olivio F DonatiInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich and University of Zurich, Switzerland.
University of Zurich · CHSiemens (Switzerland) · CHWellcome Centre for Human Neuroimaging · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the influence of body phased-array (BPA) receive coil setups on signal-to-noise ratio (SNR) and image quality (IQ) in prostate MRI.

methodsThis prospective study evaluated axial T2-weighted images (T2W-TSE) and DWI of the prostate in ten healthy volunteers with 18-channel (18CH), 30-channel and 60-channel (60CH) BPA receive coil setups. SNR and ADC values were assessed in the peripheral and transition zones (TZ). Two radiologists rated IQ features. Differences in qualitative and quantitative image features between BPA receive coil setups were compared. After correction for multiple comparisons, p-values <0.004 for quantitative and p-values <0.017 for qualitative image analysis were considered statistically significant.

resultsSignificantly higher SNR was found in T2W-TSE images in the TZ using 60CH BPA compared to 18CH BPA coil setups (15.20 ± 4.22 vs. 7.68 ± 2.37; p = 0.001). There were no significant differences between all other quantitative (T2W-TSE, p = 0.007-0.308; DWI, p = 0.024-0.574) and qualitative image features (T2W-TSE, p = 0.083-1.0; DWI, p = 0.046-1.0).

conclusion60CH BPA receive coil setup showed marginal SNR improvement in T2W-TSE images. Good IQ could be achieved with 18CH BPA coil setups.

Indexed as

18CH, BPA 18-channel body array coil30CH, BPA 30-channel body array coil60CH, BPA 60-channel body array coilANOVA, Analysis of variancesBPA, Body phased-arrayERC, Endorectal coilICC, Intra-class correlation coefficientIQR, Interquartile rangeMagnetic resonance imagingmpMRI, Multi-parametric magnetic resonance imagingProstate imagingPSTT, Post-hoc paired-sample t-testsROIs, Region of interestsSD, Standard deviationSignal-to-noise ratioSNR, Signal to noise ratioss-DWI-EPI, Single-shot diffusion-weighting spin-echo echo-planar imagingT2W-TSE, T2-weighted turbo spin echo

Identifiers

PMID33644263
PMCPMC7889823
OpenAlexW3127738236

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.