Evidence map›Paper›PMID 33644230›Full record

Trial reportBioMed research international2021

The Bony Resection Accuracy with Patient-Specific Instruments during Total Knee Arthroplasty: A Retrospective Case Series Study.

Liang Yuan, Bin Yang, Xiaohua Wang, Bin Sun, Ke Zhang, Yichen Yan, Jie Liu, Jie Yao

Open access · hybridAbstract readClinical TrialComparative Study
In one paragraph

Trial report in BioMed research international, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Liang YuanDepartment of Orthopedics, Peking University International Hospital, Beijing 102206, China.ORCID https://orcid.org/0000-0002-1160-3136
Bin YangDepartment of Orthopedics, Peking University International Hospital, Beijing 102206, China.ORCID https://orcid.org/0000-0001-7231-6678
Xiaohua WangDepartment of Orthopedics, Peking University International Hospital, Beijing 102206, China.
Bin SunDepartment of Orthopedics, Peking University International Hospital, Beijing 102206, China.
Ke ZhangDepartment of Orthopedics, Peking University International Hospital, Beijing 102206, China.
Yichen YanKey Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing 100191, China.
Jie LiuDepartment of Vascular and Endovascular Surgery, Chinese PLA General Hospital, Beijing 100853, China.ORCID https://orcid.org/0000-0002-5680-349X
Jie YaoKey Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing 100191, China.ORCID https://orcid.org/0000-0003-0044-7307
Peking University · CNBeihang University · CNChinese PLA General Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeBony resection is the primary step during total knee arthroplasty. The accuracy of bony resection was highly addressed because it was deemed to have a good relationship with mechanical line. Patient-specific instruments (PSI) were invented to copy the bony resection references from the preoperative surgical plan during a total knee arthroplasty (TKA); however, the accuracy still remains controversial. This study was aimed at finding out the accuracy of the bony resection during PSI-assisted TKA.

methodsForty-two PSI-assisted TKAs (based on full-length leg CT images) were analyzed retrospectively. Resected bones of every patient were given a CT scan, and three-dimensional radiographs were reconstructed. The thickness of each bony resection was measured with the three-dimensional radiographs and recorded. The saw blade thickness (1.27 mm) was added to the measurements, and the results represented intraoperative bone resection thickness. A comparison between intraoperative bone resection thickness and preoperatively planned thickness was conducted. The differences were calculated, and the outliers were defined as >3 mm.

resultsThe distal femoral condyle had the most accurate bone cuts with the smallest difference (median, 1.0 mm at the distal medial femoral condyle and 0.8 mm at the distal lateral femoral condyle) and the least outliers (none at the distal medial femoral condyle and 1 (2.4%) at the distal lateral femoral condyle). The tibial plateau came in second (median difference, 0.8 mm at the medial tibial plateau and 1.4 mm at the lateral tibial plateau; outliers, none at the medial tibial plateau and 1 (2.6%) at the lateral tibial plateau). Regardless of whether the threshold was set to >2 mm (14 (17.9%) at the tibial plateau vs. 12 (14.6%) at the distal femoral condyle,

conclusionThe tibial plateau and the distal femoral condyle share a similar accuracy of osteotomy with PSI. PSI have a generally good accuracy during the femur and tibia bone resection in TKA. PSI could be a kind of user-friendly tool which can simplify TKA with good accuracy.

Indexed as

Arthroplasty, Replacement, KneePrecision MedicineAgedAged, 80 and overFemaleHumansKnee JointMaleMiddle AgedRetrospective Studies

Identifiers

PMID33644230
PMCPMC7902140
OpenAlexW3131647501

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.