Evidence map›Paper›PMID 33638108›Full record

Trial reportSurgical endoscopy2022

Comparison of three-dimensional (3D) endovision system versus ultra-high-definition 4K endovision system in minimally invasive surgical procedures: a randomized-open label pilot study.

Rajinder Parshad, Shashikiran Nanjakla Jayappa, Hemanga Kumar Bhattacharjee, Suhani Suhani, Mohit Kumar Joshi, Debesh Bhoi, Lokesh Kashyap

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Surgical endoscopy, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Safety considerations in laparoscopic surgery: A narrative review.World journal of gastrointestinal endoscopy · 2022
    Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Rajinder ParshadDepartment of Surgical disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029, India.ORCID 0000-0003-3292-3611
Shashikiran Nanjakla JayappaDepartment of Surgical disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029, India. shashikiran.nj@gmail.com.ORCID 0000-0002-3105-1463
Hemanga Kumar BhattacharjeeDepartment of Surgical disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029, India.ORCID 0000-0002-1002-7077
Suhani SuhaniDepartment of Surgical disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029, India.
Mohit Kumar JoshiDepartment of Surgical disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029, India.
Debesh BhoiDepartment of Surgical disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029, India.
Lokesh KashyapDepartment of Surgical disciplines, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, 110029, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundExperimental work comparing 3-Dimensional (3D) and 4K ultra-high-definition endovision system (4K) indicates that the latter with double the resolution of standard 2D high-definition systems may provide additional visual cues to compensate for the lack of stereoscopic vision. There is paucity of studies comparing 3D and 4K system in clinical settings. This randomized study compares 3D and 4K systems in three laparoscopic procedures of increasing complexity.

methods139 patients undergoing laparoscopic cholecystectomy (60 patients), transabdominal preperitoneal (TAPP) repair (49 patients) and laparoscopic Heller's cardiomyotomy with anti- reflux procedure (30 patients) between May 2018 and February 2020 were randomized to undergo surgery using either 3D or 4K systems. Primary objective was to measure total operative time. Secondary objectives were to compare workload perceived by surgeons using SURG-TLX and surgeon satisfaction score. Timings of key surgical steps and peri-operative course of the patients was also recorded. Data were analyzed using Stata Corp. 2015.

resultsPatients undergoing surgery with 3D and 4K systems were comparable in their clinical and demographic profiles. The mean total operative time in 3D and 4K groups was comparable in cholecystectomy (52.7 vs 56.2, p = 0.50), TAPP (63.8 vs 69.6, p = 0.25) and Heller's cardiomyotomy (124.7 vs 143.3, p = 0.14) with faster hiatal dissection in 3D group (8 min, p = 0.02). Operative time was better in patients undergoing Heller's myotomy with Angle of His accentuation with 3D by 28 min (p = 0.03). Total workload was similar in 3D and 4K groups in all the procedures but mental & physical demand was lower in 3D group in Heller's cardiomyotomy (p = 0.03, p = 0.01), Surgeon satisfaction score was comparable in all three procedures.

conclusionOverall, 3D HD and 4K systems are comparable in performing laparoscopic cholecystectomy, TAPP and Heller's Cardiomyotomy. Hiatal dissection time, mental and physical task load was better with 3D in Heller's Cardiomyotomy.

Indexed as

Esophageal AchalasiaGastroesophageal RefluxHeller MyotomyLaparoscopyHumansOperative TimePilot Projects3D laparoscopy4K ultra-high-definitionHeller’s cardiomyotomyOperating timeSurg-TLXTAPPWorkload

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked