ArticleBMC pulmonary medicine2021
Inspiratory flow profile and usability of the NEXThaler, a multidose dry powder inhaler, in asthma and COPD.
Article in BMC pulmonary medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Optimizing Respiratory Care with NEXThaler: Bridging Technology and Treatment.Medical devices (Auckland, N.Z.) · 2026Review
- NEXThalerJournal of clinical medicine · 2025Article
- Development of an AI-Empowered Novel Digital Monitoring System for Inhalation Flow Profiles.Sensors (Basel, Switzerland) · 2025Article
- Small Airways Disease Affects Aerosol Deposition in Children with Severe Asthma: A Functional Respiratory Imaging Study.Journal of aerosol medicine and pulmonary drug delivery · 2024Article
- People Living with Chronic Obstructive Pulmonary Disease (COPD) and Inhalers: Insights and Suggestions from a Human Factors Study on NEXThaler.Patient preference and adherence · 2024Article
- Feedback systems in multi-dose dry powder inhalers.Postepy dermatologii i alergologii · 2023Review
- BDP/FF NEXThaler to Improve Asthma Control Status in the Real World: The NEWTON Study.Journal of asthma and allergy · 2023Article
- Measuring Peak Inspiratory Flow in Patients with Chronic Obstructive Pulmonary Disease.International journal of chronic obstructive pulmonary diseaseReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundInhaler selection is important when managing respiratory conditions; a patient's inhalation technique should be appropriate for the selected device, and patients should ideally be able to use a device successfully regardless of disease severity. The NEXThaler is a multidose dry-powder inhaler with a breath-actuated mechanism (BAM) and dose counter that activates only following inhalation, so effectively an 'inhalation counter'. We assessed inspiratory flow through the NEXThaler in two studies and examined whether inhalation triggered the BAM.
methodsThe two studies were open-label, single-arm, and single visit. One study recruited patients with asthma aged ≥ 18 years; the other recruited patients with chronic obstructive pulmonary disease (COPD) aged ≥ 40 years. All patients inhaled twice through a placebo NEXThaler. The inspiratory profile through the device was assessed for each inhalation using acoustic monitoring, with flow at and time to BAM firing, peak inspiratory flow (PIF), and total inhalation time assessed.
resultsA total of 40 patients were enrolled in the asthma study: 20 with controlled asthma and 20 with partly controlled/uncontrolled asthma. All patients were able to trigger the BAM, as evidenced by the inhalation counter activating on closing the device. Mean flow at BAM firing following first inhalation was 35.0 (range 16.3-52.3) L/min; mean PIF was 64.6 (35.0-123.9) L/min. A total of 72 patients were enrolled in the COPD study, with data analysed for 69 (mean forced expiratory volume in 1 s 48.7% predicted [17-92%]). As with the asthma study, all patients, regardless of airflow limitation, were able to trigger the BAM. Mean flow at BAM firing following first inhalation was 41.9 (26.6-57.1) L/min; mean PIF was 68.0 (31.5-125.4) L/min. Device usability was rated highly in both studies, with 5 min sufficient to train the patients, and a click heard shortly after inhalation in all cases (providing feedback on BAM firing).
conclusionsInhalation flows triggering the BAM in the NEXThaler were similar between patients with controlled and partly controlled/uncontrolled asthma, and were similar across COPD airflow limitation. All enrolled patients were able to activate the device.