ArticleBMC ophthalmology2021
Combined pars plana glaucoma drainage device placement and vitrectomy using a vitrectomy sclerotomy site for tube placement: a case series.
Article in BMC ophthalmology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 15 citations in OpenAlex.
- Challenges of Secondary Glaucoma Management Following Congenital Cataract Surgery, Penetrating Keratoplasty and Vitreoretinal Surgery.Diagnostics (Basel, Switzerland) · 2024Article
- Comparing Outcomes of Phacoemulsification and Endocyclophotocoagulation with Either Dual Blade Goniotomy (PEcK) or Two Trabecular Stents (ICE2).Clinical ophthalmology (Auckland, N.Z.) · 2023Article
- Outcomes of a combination of augmented MicroPulse and limited Continuous Wave Cyclophotocoagulation in patients with refractory glaucoma.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2022Article
- Commentary: Placement of the tube of a glaucoma drainage device: Different horses for different courses.Indian journal of ophthalmology · 2022Article
- Outcomes of Anterior Chamber, Sulcus, and Pars Plana Glaucoma Drainage Device Placement in Glaucoma Patients.Journal of ophthalmology · 2022Article
- Surgical Outcomes of Glaucoma Drainage Device Implantation in Refractory Glaucoma Patients in Thailand.Clinical ophthalmology (Auckland, N.Z.) · 2022Article
- Safety and efficacy of microinvasive glaucoma surgery with cataract extraction in patients with normal-tension glaucoma.Scientific reports · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe purpose of this study is to report the safety and efficacy of pars plana glaucoma drainage devices with pars plana vitrectomy using one of the vitrectomy sclerotomy sites for tube placement in patients with refractory glaucoma.
methodsRetrospective case series of 28 eyes of 28 patients who underwent combined pars plana glaucoma drainage device and pars plana vitrectomy between November 2016 and September 2019 at Massachusetts Eye and Ear. Main outcome measures were intraocular pressure (IOP), glaucoma medication burden, best corrected visual acuity, and complications. Statistical tests were performed with R and included Kaplan-Meier analyses, Wilcoxon paired signed-rank tests, and Fisher tests.
resultsMean IOP decreased from 22.8 mmHg to 11.8 mmHg at 1.5 years (p = 0.002), and mean medication burden decreased from 4.3 to 2.1 at 1.5 years (p = 0.004). Both IOP and medication burden were significantly lower at all follow-up time points. The probability of achieving 5 < IOP ≤ 18 mmHg with at least 20% IOP reduction from preoperative levels was 86.4% at 1 year and 59.8% at 1.5 years. At their last visit, three eyes (10.7%) achieved complete success with IOP reduction as above without medications, and 14 eyes (50.0%) achieved qualified success with medications. Hypotony was observed in 1 eye (3.6%) prior to 3 months postoperatively and 0 eyes after 3 months. Visual acuity was unchanged or improved in 23 eyes (82.1%) at their last follow-up. Two patients had a visual acuity decrease of > 2 lines. Two eyes required subsequent pars plana vitrectomies for tube obstruction, and one eye had transient hypotony.
conclusionsThe results of pars plana glaucoma drainage device and pars plana vitrectomy using one of the vitrectomy sclerotomy sites for tube placement are promising, resulting in significant IOP and medication-burden reductions through postoperative year 1.5 without additional risk of postoperative complications. Inserting glaucoma drainage devices into an existing vitrectomy sclerotomy site may potentially save surgical time by obviating the need to create another sclerotomy for tube placement and suture one of the vitrectomy ports.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.