Syncope triggered by atrial flutter in a patient with a pacemaker: cross-stimulation-a case report.

Olga Durán-Bobin, Francisco Crespo-Mancebo, Juliana Elices-Teja, Carlos González-Juanatey

Open access · goldAbstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 50% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Olga Durán-BobinCardiac Arrhythmia Unit, Cardiology Department, Hospital Universitario Lucus Augusti, C/Ulises Romero s/n, 27003, Lugo, Spain.
Francisco Crespo-ManceboCardiac Arrhythmia Unit, Cardiology Department, Hospital Universitario Lucus Augusti, C/Ulises Romero s/n, 27003, Lugo, Spain.
Juliana Elices-TejaCardiac Arrhythmia Unit, Cardiology Department, Hospital Universitario Lucus Augusti, C/Ulises Romero s/n, 27003, Lugo, Spain.
Carlos González-JuanateyCardiology Department, Hospital Universitario Lucus Augusti, Lugo, Spain.
Hospital Universitario Lucus Augusti · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSyncope in a patient with a pacemaker is a serious event requiring urgent action to ascertain its cause. Around 5% of cases are due to a pacemaker system malfunction. CASE SUMMARY: An 82-year-old man underwent dual-chamber permanent pacemaker implantation due to intermittent high-degree atrioventricular block (AVB) in sinus rhythm. Nine months later, the patient reported episodes of syncope. The chest X-ray showed both leads to be at their expected positions. The electrocardiography (ECG) showed common atrial flutter. Ventricular capture during pacing in atrial demand pacing (AAI) mode confirmed cross-stimulation due to the switching of the atrial and ventricular leads at the pacemaker header. DISCUSSION: Cross-stimulation is a rare possibility in a differential diagnosis of causes of syncope. The diagnosis is frequently made during the procedure or a few hours later. The lack of symptoms during 9 months in this case was likely due to the patient having normal sinus rhythm with preserved AV conduction most of the time, as well as ventricular capture from the atrial lead related to non-sensed P waves. When atrial arrhythmias occurred, the sensing of the F waves inhibited ventricular pacing. In order to avoid this complication, in patients with intermittent bradycardia, pacing at a slightly higher heart rate during implantation of the device should be recommended to see the chamber paced with the surface ECG connected to the device interrogator. The ECG and electrogram (EGM) should correlate during device interrogation in order to identify this complication.).

Indexed as

Case reportCross-stimulationPacemaker dysfunctionSyncope

Identifiers

PMID33629026
PMCPMC7889715
OpenAlexW3132311598

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.