ArticleEuropean heart journal. Case reports2021
Syncope triggered by atrial flutter in a patient with a pacemaker: cross-stimulation-a case report.
Article in European heart journal. Case reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSyncope in a patient with a pacemaker is a serious event requiring urgent action to ascertain its cause. Around 5% of cases are due to a pacemaker system malfunction. CASE SUMMARY: An 82-year-old man underwent dual-chamber permanent pacemaker implantation due to intermittent high-degree atrioventricular block (AVB) in sinus rhythm. Nine months later, the patient reported episodes of syncope. The chest X-ray showed both leads to be at their expected positions. The electrocardiography (ECG) showed common atrial flutter. Ventricular capture during pacing in atrial demand pacing (AAI) mode confirmed cross-stimulation due to the switching of the atrial and ventricular leads at the pacemaker header. DISCUSSION: Cross-stimulation is a rare possibility in a differential diagnosis of causes of syncope. The diagnosis is frequently made during the procedure or a few hours later. The lack of symptoms during 9 months in this case was likely due to the patient having normal sinus rhythm with preserved AV conduction most of the time, as well as ventricular capture from the atrial lead related to non-sensed P waves. When atrial arrhythmias occurred, the sensing of the F waves inhibited ventricular pacing. In order to avoid this complication, in patients with intermittent bradycardia, pacing at a slightly higher heart rate during implantation of the device should be recommended to see the chamber paced with the surface ECG connected to the device interrogator. The ECG and electrogram (EGM) should correlate during device interrogation in order to identify this complication.).