Evidence map›Paper›PMID 33624598›Full record

ArticleNan fang yi ke da xue xue bao = Journal of Southern Medical University2021

[Four-dimensional cone-beam CT reconstruction based on motion-compensated robust principal component analysis].

Y Mo, J Liu, Q Li, J Ma, H Zhang

Abstract read
In one paragraph

Article in Nan fang yi ke da xue xue bao = Journal of Southern Medical University, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Y MoDepartment of Biomedical Engineering, Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou 510515, China.
J LiuDepartment of Biomedical Engineering, Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou 510515, China.
Q LiDepartment of Biomedical Engineering, Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou 510515, China.
J MaDepartment of Biomedical Engineering, Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou 510515, China.
H ZhangDepartment of Biomedical Engineering, Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou 510515, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo propose a motion compensation reconstruction method based on robust principal component analysis (RPCA) to reduce the influence of streak artifacts on accurate estimation of interphase motion deformation fields.

objectiveWe propose a RPCA motion compensation reconstruction algorithm to improve the estimation of motion deformation fields based on the traditional MC-FDK algorithm. RPCA was used to decompose the cone-beam computed tomography (CBCT) images into low-rank and sparse components, and the motion deformation fields between different phase images were then estimated using Horn and Schunck optical flow method from the low-rank images to reduce the influence of striping artifacts on the accuracy of estimation of interphase motion deformation fields. The performance of the algorithm was evaluated using simulation data and real data. The simulation phantom data was obtained by back-projection of 4D-CT images acquired from Philips 16-slice spiral CT using MATLAB software programming according to the scanning geometry of Varian Edge accelerator. The real patient data were obtained using the Elekta Synergy system of CBCT scanning system with half-fan mode CB projection data from lung cancer patients.

objectiveCompared with images reconstructed using the traditional MC-FDK algorithm, the reconstructed image using the proposed method had clearer tissue boundaries with reduced motion artifact was reduced. The results of phantom data reconstruction showed that compared with the MC- FDK algorithm, the proposed algorithms resulted in improvements of PSNR by 25.4% and SSIM by 7.6%; compared with the FDK algorithm, PSNR was improved by 37.9% and SSIM by 17.6%.

objectiveThe proposed algorithm can achieve accurate estimation of inter-phase motion deformation fields and improve the quality of the reconstructed CBCT images.

Indexed as

ArtifactsFour-Dimensional Computed TomographyCone-Beam Computed TomographyHumansMotionPrincipal Component Analysis4-dimensional cone-beam computed tomographymotion compensationrobust principal component analysis

Identifiers

PMID33624598
PMCPMC7905249

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.