Impact of optical coherence tomography scan direction on the reliability of peripapillary retinal nerve fiber layer measurements.

Abinaya Priya Venkataraman, Josefine Andersson, Lina Fivelsdal, Maria Nilsson, Alberto Domínguez-Vicent

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.3field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Abinaya Priya VenkataramanDivision of Eye and Vision, Department of Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden.ORCID 0000-0002-2155-7030
Josefine AnderssonDivision of Eye and Vision, Department of Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden.ORCID 0000-0003-2154-3066
Lina FivelsdalDivision of Eye and Vision, Department of Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden.ORCID 0000-0002-3568-3767
Maria NilssonDivision of Eye and Vision, Department of Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden.
Alberto Domínguez-VicentDivision of Eye and Vision, Department of Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden.
Karolinska Institutet · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the intradevice repeatability and agreement for peripapillary retinal nerve fiber layer (pRNFL) measurements in healthy eyes with two different scan directions and two different number of B scans.

methodspRNFL was measured with a spectral domain optical coherence tomography on 54 healthy participants. Three-dimensional optic disc scans (6 mm x 6 mm) were performed on the right eye of the participants. Two repeated scans were performed in four different settings: H1: Horizontal scan with 512 A-scans x 96 B-scans; H2: Horizontal scan with 512 A-scans x 128 B-scans; V1: Vertical scan with 512 A-scans x 96 B-scans; V2: Vertical scan with 512 A-scans x 128 B-scans. The pRNFL thickness was evaluated in twelve clock-hour sector in a circle of 3.45 mm diameter centred at the optic disc. Repeatability and agreement were assessed with within subject standard deviation (Sw) and Bland-Altman test respectively.

resultsThe repeatability of pRNFL measurements varied depending on the scan direction and sectors. The repeatability for the horizontal sectors were better with H1 and H2, with sector 9 having the best Sw (< 3 μm). The repeatability for the vertical sectors were better with V1 and V2 with sector 5 and 9 having the best Sw (< 4 μm). The repeatability with vertical scan was more symmetric among the sectors than with horizontal scans. The repeatability metrics of the sectors did not vary much between H1 and H2 (difference < 2 μm) and between V1 and V2 (difference < 3.2 μm). Comparing horizontal and vertical scans, the vertical sectors had larger limits of agreement of about 45 μm.

conclusionThe reliability of the pRNFL thickness measurements is dependent on the direction of the scan and independent on the numbers of B-scans. Vertical scans for pRNFL gives more homogeneous repeatability across the different sectors.

Indexed as

Retinal NeuronsAdolescentAdultFemaleHealthy VolunteersHumansMaleNerve FibersReproducibility of ResultsRetinaTomography, Optical CoherenceYoung Adult