ArticleInternational journal of computer assisted radiology and surgery2021
Patient-specific desktop 3D-printed guides for pelvic tumour resection surgery: a precision study on cadavers.
Article in International journal of computer assisted radiology and surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Enhancing Precision in Pelvic Tumor Reconstruction: Early Experience and Iterative Design of Custom 3D-Printed Implants.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2026Article
- Feasibility and Accuracy of a Dual-Function AR-Guided System for PSI Positioning and Osteotomy Execution in Pelvic Tumour Surgery: A Cadaveric Study.Bioengineering (Basel, Switzerland) · 2025Article
- Article
- AR-assisted surgery: Precision placement of patient specific hip implants based on 3D printed PSIs.Healthcare technology letters · 2024Article
- 3D-printed Multifunctional Guide Plate for Fenestration and Screws Drill in Proximal Femoral Benign Tumor.Orthopaedic surgery · 2024Article
- Fluoroscopically calibrated 3D-printed patient-specific instruments improve the accuracy of osteotomy during bone tumor resection adjacent to joints.3D printing in medicine · 2024Article
- How Does Customized Cutting Guide Design Affect Accuracy and Ergonomics in Pelvic Tumor Resection? A Study in Cadavers.Clinical orthopaedics and related research · 2024Article
- Current Concepts in the Resection of Bone Tumors Using a Patient-Specific Three-Dimensional Printed Cutting Guide.Current oncology (Toronto, Ont.) · 2023Review
- Multifunctional Medical Grade Resin with Enhanced Mechanical and Antibacterial Properties: The Effect of Copper Nano-Inclusions in Vat Polymerization (VPP) Additive Manufacturing.Journal of functional biomaterials · 2022Article
- Digital chain for pelvic tumor resection with 3D-printed surgical cutting guides.Frontiers in bioengineering and biotechnology · 2022Article
- Augmented Reality as a Tool to Guide PSI Placement in Pelvic Tumor Resections.Sensors (Basel, Switzerland) · 2021Article
- 3D printed composite model of pelvic osteochondroma and nerve roots.3D printing in medicine · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
purpose3D-printed patient-specific instruments have become a useful tool to improve accuracy in pelvic tumour resections. However, their correct placement can be challenging in some regions due to the morphology of the bone, so it is essential to be aware of the possible placement errors in each region. In this study, we characterize these errors in common pelvic osteotomies.
methodsWe conducted an experiment with 9 cadaveric specimens, for which we acquired a pre-operative computed tomography scan. Small PSIs were designed for each case following a realistic surgical approach for four regions of the pelvis: iliac crest (C), supra-acetabular (S), ischial (I), and pubic (P). Final surgical placement was based on a post-operative scan. The resulting positions were compared with pre-operative planning, obtaining translations, rotations, and maximum osteotomy deviations in a local reference frame defined based on the bone's morphology.
resultsMean translations and rotations in the direction of the osteotomy plane were as follows: C = 5.3 mm, 6.7°; S = 1.8 mm, 5.1°; I = 1.5 mm, 3.4°; P = 1.8 mm, 3.5°. Mean translations in the remaining axes were below 2 mm. Maximum osteotomy deviations (75% of cases) were below 11.8 mm in C (7.8 mm for half-length), 7.8 mm in S (5.5 mm for half-length), 5.5 mm in I, and 3.7 mm in P.
conclusionWe have characterized placement errors for small PSIs in four regions of the pelvis. Our results show high errors in C and S PSIs in the direction of the resection plane's normal, and thus large osteotomy deviations. Deviations in short osteotomies in S, I and P and placement errors in the remaining directions were low. The PSIs used in this study are biocompatible and can be produced with a desktop 3D printer, thus minimizing manufacturing cost.
Indexed as
Identifiers
33616839What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.