Evidence map›Paper›PMID 33615738›Full record

ArticleJournal of medical radiation sciences2020

Evaluation of a deformable image registration quality assurance tool for head and neck cancer patients.

Molly Mee, Kate Stewart, Marika Lathouras, Helen Truong, Catriona Hargrave

Abstract readEvaluation Study
In one paragraph

Article in Journal of medical radiation sciences, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Deformable dose accumulation is required for adaptive radiotherapy practice.Journal of applied clinical medical physics · 2024
    Article
  5. Article
  6. Article
  7. Article
  8. Deformable image registration in radiation therapy.Journal of medical radiation sciences · 2020
    Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Molly MeeFaculty of Health, School of Clinical Sciences, Queensland University of Technology, Brisbane, Queensland, Australia.ORCID https://orcid.org/0000-0001-7493-3813
Kate StewartFaculty of Health, School of Clinical Sciences, Queensland University of Technology, Brisbane, Queensland, Australia.ORCID https://orcid.org/0000-0001-8676-6565
Marika LathourasDepartment of Radiation Oncology, Royal Brisbane and Women's Hospital, Metro North Health Service District, Herston, Queensland, Australia.ORCID https://orcid.org/0000-0002-9031-864X
Helen TruongDepartment of Radiation Oncology, Royal Brisbane and Women's Hospital, Metro North Health Service District, Herston, Queensland, Australia.
Catriona HargraveFaculty of Health, School of Clinical Sciences, Queensland University of Technology, Brisbane, Queensland, Australia.ORCID https://orcid.org/0000-0003-4298-2228

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionA challenge in implementing deformable image registration (DIR) in radiation therapy planning is effectively communicating registration accuracy to the radiation oncologist. This study aimed to evaluate the MIM® quality assurance (QA) tool for rating DIR accuracy.

methodsRetrospective DIR was performed on CT images for 35 head and neck cancer patients. The QA tool was used to rate DIR accuracy as good, fair or bad. Thirty registered patient images were assessed independently by three RTs and a further five patients assessed by five RTs. Ratings were evaluated by comparison of Hausdorff Distance (HD), Mean Distance to Agreement (MDA), Dice Similarity Coefficients (DSC) and Jacobian determinants for parotid and mandible subregions on the two CTs post-DIR. Inter-operator reliability was assessed using Krippendorff's alpha coefficient (KALPA). Rating time and volume measures for each rating were also calculated.

resultsQuantitative metrics calculated for most anatomical subregions reflected the expected trend by registration accuracy, with good obtaining the most ideal values on average (HD = 7.50 ± 3.18, MDA = 0.64 ± 0.47, DSC = 0.90 ± 0.07, Jacobian = 0.95 ± 0.06). Highest inter-operator reliability was observed for good ratings and within the parotids (KALPA 0.66-0.93), whilst ratings varied the most in regions of dental artefact. Overall, average rating time was 33 minutes and the least commonly applied rating by volume was fair.

conclusionResults from qualitative and quantitative data, operator rating differences and rating time suggest highlighting only bad regions of DIR accuracy and implementing clinical guidelines and RT training for consistent and efficient use of the QA tool.

Indexed as

Head and Neck NeoplasmsQuality Assurance, Health CareTomography, X-Ray ComputedFemaleHumansImage Processing, Computer-AssistedMaleRadiotherapy Planning, Computer-AssistedRetrospective Studiesdeformable image registrationquality assuranceradiation therapytreatment planning

Identifiers

PMID33615738
PMCPMC7754017

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.