Device Prototype for Vaginal Delivery of Extremely Preterm Fetuses in the Breech Presentation.
Article in Journal of medical devices, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
- From intra- to extra-uterine: early phase design of a transfer to extra-uterine life support through medical simulation.Frontiers in medical technology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Vaginal delivery is typically avoided in the extremely preterm breech population due to the concern of entrapment by the cervix of the aftercoming head. A mechanical device concept is presented to enable vaginal delivery by preventing retraction of the cervix against the fetus during delivery. The two-part device was designed to dilate the cervix, prevent prolapse of small fetal parts and maintain sufficient dilation during delivery. The two-part device was designed and manufactured with the following modules: an inflatable saline-filled cervical balloon for dilation and a cervical retractor composed of semirigid beams to stabilize the cervix and maintain adequate dilation. The device was tested using a cervical phantom designed to simulate the compressive force the cervix exerts. The cervical balloon reached a maximum dilation of 8.5 cm, after which there was leakage of saline from the balloon. While this dilation was less than the target goal of 10 cm, the leaking was attributed to prototype manufacturing defects, which could be resolved with further development. The cervical retractor was able to withstand between 1-3 kPa. Although estimates of cervical pressure values can be upward of 30 kPa, there are no in vivo measurements to formally identify the pressure values for patients in preterm labor. This device serves as a viable proof-of-concept for utilizing an inflatable balloon device to prevent cervical retraction in the setting of extremely preterm vaginal breech delivery. Further manufacturing improvements and design changes could improve the device for continued development and testing.