ArticleMedical physics2021

Technical and clinical study of x-ray-based surface echo probe tracking using an attached fiducial apparatus.

Lindsay E Bodart, Benjamin R Ciske, Jonathan Le, Nicole M Reilly, Roderick C Deaño, Steven M Ewer, Parag Tipnis, Peter S Rahko, Martin G Wagner, Amish N Raval and 1 more

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. An X-Ray C-Arm Guided Automatic Targeting System for Histotripsy.IEEE transactions on bio-medical engineering · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 1 institution in 1 country.

Lindsay E BodartDepartment of Medical Physics, University of Wisconsin - Madison, Madison, WI, USA.
Benjamin R CiskeDepartment of Medicine, University of Wisconsin - Madison, Madison, WI, USA.
Jonathan LeDepartment of Medicine, University of Wisconsin - Madison, Madison, WI, USA.
Nicole M ReillyDepartment of Medicine, University of Wisconsin - Madison, Madison, WI, USA.
Roderick C DeañoDepartment of Medicine, University of Wisconsin - Madison, Madison, WI, USA.
Steven M EwerDepartment of Medicine, University of Wisconsin - Madison, Madison, WI, USA.
Parag TipnisDepartment of Medicine, University of Wisconsin - Madison, Madison, WI, USA.
Peter S RahkoDepartment of Medicine, University of Wisconsin - Madison, Madison, WI, USA.
Martin G WagnerDepartment of Medical Physics, University of Wisconsin - Madison, Madison, WI, USA.
Amish N RavalDepartment of Medicine, University of Wisconsin - Madison, Madison, WI, USA.
Michael A SpeidelDepartment of Medical Physics, University of Wisconsin - Madison, Madison, WI, USA.
University of Wisconsin–Madison · US

Funding

BIOTECHNOLOGY TRAINING PROGRAMT32GM008349 · NIGMS · UNIVERSITY OF WISCONSIN-MADISON · PI FOX, BRIAN G · 1989 to 2019
$22.5M
NIGMS NIH HHS T32 GM008349NIH HHS T32GM008349
6 · The paper itself

Abstract

purposeSeveral types of structural heart intervention (SHI) use information from multiple imaging modalities to complete an interventional task. For example, in transcatheter aortic valve replacement (TAVR), placement and deployment of a bioprosthetic aortic valve in the aorta is primarily guided by x-ray fluoroscopy (XRF), and echocardiography provides visualization of cardiac anatomy and blood flow. However, simultaneous interpretation of independent x-ray and echo displays remains a challenge for the interventionalist. The purpose of this work was to develop a novel echo/x-ray co-registration solution in which volumetric transthoracic echo (TTE) is transformed to the x-ray coordinate system by tracking the three-dimensional (3D) pose of a probe fiducial attachment from its appearance in two-dimensional (2D) x-ray images.

methodsA fiducial attachment for a commercial TTE probe consisting of rings of high-contrast ball bearings was designed and fabricated. The 3D pose (position and orientation) of the fiducial attachment is estimated from a 2D x-ray image using an algorithm in which a virtual point cloud model of the attachment is iteratively rotated, translated, and forward-projected onto the image until the average sum-of-squares of grayscale values at the projected points is minimized. Fiducial registration error (FRE) and target registration error (TRE) of this approach were evaluated in phantom studies using TAVR-relevant gantry orientations and four standard acoustic windows for the TTE probe. A patient study was conducted to assess the clinical suitability of the fiducial attachment prototype during TTE imaging of patients undergoing SHI. TTE image quality for the task of guiding a transcatheter procedure was evaluated in a reviewer study.

resultsThe 3D FRE ranged from 0.32 ± 0.03 mm (mean ± SD) to 1.31 ± 0.05 mm, depending on C-arm orientation and probe acoustic window. The 3D TRE ranged from 1.06 ± 0.03 mm to 2.42 ± 0.06 mm. Fiducial pose estimation was stable when >75% of the fiducial markers were visible in the x-ray image. A panel of reviewers graded the presentation of heart valves in TTE images from 48 SHI patients. While valve presentation did not differ significantly between acoustic windows (P > 0.05), the mitral valve did achieve a significantly higher image quality compared to the aortic and tricuspid valves (P < 0.001). Overall, reviewers perceived sufficient image quality in 76.5% of images of the mitral valve, 54.9% of images of the aortic valve, and 48.6% of images of the tricuspid valve.

conclusionsFiducial-based tracking of a commercial TTE probe is compatible with clinical SHI workflows and yields 3D target registration error of less than 2.5 mm for a variety of x-ray gantry geometries and echo probe acoustic windows. Although TTE image quality with respect to target valve anatomy was sufficient for the majority of cases examined, prescreening of patients for sufficient TTE quality would be helpful.

Indexed as

Aortic ValveFiducial MarkersFluoroscopyHumansImaging, Three-DimensionalPhantoms, ImagingReproducibility of ResultsX-Raysechocardiographyimage-guided interventionpose estimationregistrationx-ray fluoroscopy

Identifiers

PMID33608930
PMCPMC8152800
OpenAlexW3130288351

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.