Evidence map›Paper›PMID 33608851›Full record

ArticleJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2022

The prevalence of image degradation due to motion in rest-stress rubidium-82 imaging on a SiPM PET-CT system.

Ian S Armstrong, Matthew J Memmott, Charles Hayden, Parthiban Arumugam

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Detection and correction of patient motion in dynamicJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023
    Article
  2. Data-driven motion correction rescues interpretation of rubidium PET scan with extreme breathing artifacts.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023
    Article
  3. Moving forward with motion reduction, detection and correction in cardiac PET.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors.

Ian S ArmstrongNuclear Medicine, Manchester University NHS Foundation Trust, Oxford Road, Manchester, UK. Ian.Armstrong@mft.nhs.uk.ORCID 0000-0003-2507-6012
Matthew J MemmottNuclear Medicine, Manchester University NHS Foundation Trust, Oxford Road, Manchester, UK.
Charles HaydenSiemens Medical Solutions USA, Inc., Molecular Imaging, Knoxville, TN, USA.
Parthiban ArumugamNuclear Medicine, Manchester University NHS Foundation Trust, Oxford Road, Manchester, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMotion of the heart is known to affect image quality in cardiac PET. The prevalence of motion blurring in routine cardiac PET is not fully appreciated due to challenges identifying subtle motion artefacts. This study utilizes a recent prototype Data-Driven Motion Correction (DDMC) algorithm to generate corrected images that are compared with non-corrected images to identify visual differences in relative rubidium-82 perfusion images due to motion.

methods300 stress and 300 rest static images were reconstructed with DDMC and without correction (NMC). The 600 DDMC/NMC image pairs were assigned Visual Difference Score (VDS). The number of non-diagnostic images were noted. A "Dwell Fraction" (DF) was derived from the data to quantify motion and predict image degradation.

resultsMotion degradation (VDS = 1 or 2) was evident in 58% of stress images and 33% of rest images. Seven NMC images were non-diagnostic-these originated from six studies giving a 2% rate of non-diagnostic studies due to motion. The DF metric was able to effectively predict image degradation. The DDMC heart identification and tracking was successful in all images.

conclusionMotion degradation is present in almost half of all relative perfusion images. The DDMC algorithm is a robust tool for predicting, assessing and correcting image degradation.

Indexed as

Positron-Emission TomographyPositron Emission Tomography Computed TomographyArtifactsHumansImage Processing, Computer-AssistedMovementRubidium RadioisotopesRubidium-82Rubidium Radioisotopes