Evidence map›Paper›PMID 33599774›Full record

ArticleJAMA network open2021

Feasibility of Imaging-Based 3-Dimensional Models to Design Patient-Specific Osteosynthesis Plates and Drilling Guides.

Frank F A IJpma, Anne M L Meesters, Bram B J Merema, Kaj Ten Duis, Jean-Paul P M de Vries, Hester Banierink, Klaus W Wendt, Joep Kraeima, Max J H Witjes

Abstract read
In one paragraph

Article in JAMA network open, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
31citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

31 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. [Application progress of customized steel plates in osteotomy and orthopedic treatment of knee osteoarthritis].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2025
    Review
  5. Accuracy of 3D-navigated screw fixation in pelvic ring fractures: a single-centre consecutive observational case series.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025
    Observational
  6. Navigation and intraoperative imaging in pelvic and acetabular trauma.OTA international : the open access journal of orthopaedic trauma · 2025
    Article
  7. Pre-contoured Plate Fit Assessment for Acetabular Fractures.Annals of biomedical engineering · 2025
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Development of patient-specific osteosynthesis including 3D-printed drilling guides for medial tibial plateau fracture surgery.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024
    Article
  16. 3D-assisted corrective osteotomies of the distal radius: a comparison of pre-contoured conventional implants versus patient-specific implants.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024
    Article
  17. Review
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

9 authors.

Frank F A IJpmaDepartment of Surgery, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.
Anne M L MeestersDepartment of Surgery, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.
Bram B J Merema3D Lab, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.
Kaj Ten DuisDepartment of Surgery, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.
Jean-Paul P M de VriesDepartment of Surgery, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.
Hester BanierinkDepartment of Surgery, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.
Klaus W WendtDepartment of Surgery, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.
Joep Kraeima3D Lab, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.
Max J H Witjes3D Lab, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Importance: In acetabular fracture surgery, achieving an optimal reconstruction of the articular surface decreases the risk of osteoarthritis and the subsequent need for total hip arthroplasty. However, no one-size-fits-all osteosynthesis plate is available owing to differences in fracture patterns and variations in pelvic anatomy. Currently, osteosynthesis plates need to be manually contoured intraoperatively, often resulting in inadequate reduction and fixation of the fractured segments. Objective: To determine the feasibility and accuracy of a novel concept of fast-track 3-dimensional (3-D) virtual surgical planning and patient-specific osteosynthesis for complex acetabular fracture surgery. Design, Setting, and Participants: This case series study examines the use of patient-specific osteosynthesis plates for patients needing operative treatment for displaced associated-type acetabular fractures at a tertiary university-affiliated referral center and level 1 trauma center between January 1, 2017, and December 31, 2018. Models were created in 3-D based on computed tomography (CT) data, fractures were virtually reduced, and implant positions were discussed in a multidisciplinary team of clinicians and engineers. Patient-specific osteosynthesis plates with drilling guides were designed, produced, sterilized and clinically applied within 4 days. Data were analyzed at the 1-year follow-up. Exposures: Development and clinical implementation of personalized fracture surgery. Main Outcomes and Measures: The primary outcome was the quality of the reduction as determined by the postoperative CT scan. The secondary outcomes were accuracy of the screw placement and clinical outcome using patient-reported outcome measures. Results: Ten patients with a median (range) age of 63 (46-79) years with an acetabular fracture were included. The median (interquartile range [IQR]) preoperative gap was 20 (15-22) mm, and the median (IQR) step-off was 5 (3-11) mm. Postoperatively, the median (IQR) gap was reduced to 3 (2-5) mm (P = .005), and the median (IQR) step-off was reduced to 0 (0-2) mm (P = .01), indicating good fracture reduction, indicating good fracture reduction. The mean difference between the preoperative and postoperative gap was 14.6 (95% CI, 10-19) mm, and the mean difference in step-off was 5.7 (95% CI, 2-9) mm. The median (IQR) difference in screw direction between the planning and actual surgery was only 7.1° (7°-8°). All patients retained their native hip and reported good physical functioning at follow-up. Conclusions and Relevance: These findings suggest that 3-D virtual surgical planning, manufacturing, and clinical application of patient-specific osteosynthesis plates and drilling guides was feasible and yielded good clinical outcomes. Fast-track personalized surgical treatment could open a new era for the treatment of complex injuries.

Indexed as

Bone PlatesAcetabulumAgedFeasibility StudiesFemaleFracture Fixation, InternalFractures, BoneHumansImaging, Three-DimensionalMaleManufacturing IndustryMiddle AgedModels, AnatomicPatient Reported Outcome MeasuresPrinting, Three-DimensionalTomography, X-Ray Computed

Identifiers

PMID33599774
PMCPMC7893502

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.