Evidence map›Paper›PMID 33598418›Full record

ArticleQatar medical journal2020

Management of critical tracheal stenosis with a straw sized tube (Tritube): Case report.

Nabil Shallik, Mohamed Elarref, Odai Khamash, Abdelrahman Abdelaal, Mayed Radi Alkhafaji, Hossam Makki, Abelrahman Abusabeib, Abbas Moustafa, Abhishek Menon

Open access · diamondAbstract readCase Reports
In one paragraph

Article in Qatar medical journal, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 13 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 2 countries.

Nabil Shallik
Mohamed Elarref
Odai KhamashHamad Medical Corporation, Anesthesia, ICU and Perioperative Medicine Department, P.O. Box. 3050, Doha, Qatar, E-mail: nshallik@hamad.qa.
Abdelrahman AbdelaalHamad Medical Corporation, Surgery Department, P.O. Box. 3050, Doha, Qatar.
Mayed Radi Alkhafaji
Hossam Makki
Abelrahman AbusabeibHamad Medical Corporation, Surgery Department, P.O. Box. 3050, Doha, Qatar.
Abbas MoustafaHamad Medical Corporation, Clinical Radiology and Medical Imaging Department, P.O. Box. 3050, Doha, Qatar.
Abhishek MenonHamad Medical Corporation, ENT - ORL Department, P.O. Box. 3050, Doha, Qatar.
Hamad Medical Corporation · QAWeill Cornell Medical College in Qatar · QATanta University · EG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Imminent upper airway obstruction due to life-threatening tracheal stenosis of any cause is a challenging situation. We present a challenging case of total thyroidectomy for a malignant, invasive, and highly vascularized thyroid carcinoma that has invaded the surrounding tissues, including the sternum and mediastinum, resulting in compression of the trachea with indentation. The patient presented with a significant symptomatic tracheal stenosis, the narrowest area of that was 4 mm. Airway management in such cases presents a particular challenge to the anesthesiologists, especially considering that the option of tracheostomy is very difficult most of the time due to the highly swollen thyroid and distorted anatomy. A meticulous history of the patient's illness had been taken, and a comprehensive preoperative evaluation was conducted, including construction of a 3D model airway, virtual endoscopy, and transnasal tracheoscopy. On the day of the surgery, the airway was managed through spontaneous respiration using intravenous anesthesia and the high-flow nasal oxygen (STRIVE-Hi) technique. It was then secured with intubation using a straw endotracheal tube (Tritube®) with an internal diameter (ID) of 2.4 mm and an outer diameter of 4.4 mm with the help of a fiberscope and D-MAC blade of a video laryngoscope. At the end of the procedure, the airway was checked with a fiber optic scope, which showed an improvement in the narrowed area. This enabled us to replace the Tritube with an adult cuffed ETT of size 6.5 mm ID, and the patient was transferred intubated to the surgical ICU. Two days later, the patient's tracheal diameter was evaluated with the help of a fiberoptic scope and extubated successfully in the operating theater.

Indexed as

evone ventilatorflow controlled ventilationSTRIVE-Hithyroid cancertracheal stenosistransnasal tracheoscopytritube

Identifiers

PMID33598418
PMCPMC7842837
OpenAlexW3126718618

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.