Evidence map›Paper›PMID 33596236›Full record

ArticlePloS one2021

Performance of SARS-CoV-2 serology tests: Are they good enough?

Isabelle Piec, Emma English, Mary Annette Thomas, Samir Dervisevic, William D Fraser, William Garry John

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 2 pooled it
1.0field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 2 syntheses or guidelines pooled it, 17 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Isabelle PiecBioAnalytical Facility, Faculty of Medicine, University of East Anglia, Norwich, United Kingdom.ORCID 0000-0002-0648-1330
Emma EnglishFaculty of Medicine and Health, University of East Anglia, Norwich, United Kingdom.ORCID 0000-0002-0480-6744
Mary Annette ThomasWEQAS, Cardiff and Vale University Health Board, Cardiff, United Kingdom.
Samir DervisevicVirology Department, Norfolk and Norwich University Hospitals, Norwich, United Kingdom.
William D FraserBioAnalytical Facility, Faculty of Medicine, University of East Anglia, Norwich, United Kingdom.
William Garry JohnFaculty of Medicine and Health, University of East Anglia, Norwich, United Kingdom.
University of East Anglia · GBCardiff and Vale University Health Board · GBNorfolk and Norwich University Hospitals NHS Foundation Trust · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In the emergency of the SARS-CoV-2 pandemic, great efforts were made to quickly provide serology testing to the medical community however, these methods have been introduced into clinical practice without the complete validation usually required by the regulatory organizations. SARS-CoV-2 patient samples (n = 43) were analyzed alongside pre-pandemic control specimen (n = 50), confirmed respiratory infections (n = 50), inflammatory polyarthritis (n = 22) and positive for thyroid stimulating immunoglobulin (n = 30). Imprecision, diagnostic sensitivity and specificity and concordance were evaluated on IgG serologic assays from EuroImmun, Epitope Diagnostics (EDI), Abbott Diagnostics and DiaSorin and a rapid IgG/IgM test from Healgen. EDI and EuroImmun imprecision was 0.02-14.0% CV. Abbott and DiaSorin imprecision (CV) ranged from 5.2%-8.1% and 8.2%-9.6% respectively. Diagnostic sensitivity of the assays was 100% (CI: 80-100%) for Abbott, EDI and EuroImmun and 95% (CI: 73-100%) for DiaSorin at ≥14 days post PCR. Only the Abbott assay had a diagnostic specificity of 100% (CI: 91-100%). EuroImmun cross-reacted in 3 non-SARS-CoV-2 respiratory infections and 2 controls. The DiaSorin displayed more false negative results and cross-reacted in six cases across all conditions tested. EDI had one cross-reactive sample. The Healgen rapid test showed excellent sensitivity and specificity. Overall, concordance of the assays ranged from 76.1% to 97.9%. Serological tests for SARS-CoV-2 showed good analytical performance. The head-to-head analysis of samples revealed differences in results that may be linked to the use of nucleocapsid or spike proteins. The point of care device tested demonstrated adequate performance for antibody detection.

Indexed as

Antibodies, ViralBrazilClinical Laboratory TechniquesCOVID-19COVID-19 Serological TestingCross ReactionsHumansImmunoglobulin GImmunoglobulin MPandemicsPoint-of-Care SystemsSARS-CoV-2Sensitivity and SpecificityAntibodies, ViralImmunoglobulin GImmunoglobulin M

Identifiers

PMID33596236
PMCPMC7888604
OpenAlexW3129511279

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.