Evidence map›Paper›PMID 33595820›Full record

ArticleInternational urology and nephrology2021

Failure of ureteral stents subject to extrinsic ureteral obstruction and stent occlusions.

Tal Amitay-Rosen, Alon Nissan, Yaniv Shilo, Ishai Dror, Brian Berkowitz

Abstract read
PubMed Publisher
In one paragraph

Article in International urology and nephrology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 16 citations in OpenAlex.

  1. Review
  2. Magnetic resonance imaging of in vitro urine flow in single and tandem stented ureters subject to extrinsic ureteral obstruction.International journal of urology : official journal of the Japanese Urological Association · 2022
    Article
  3. Article
  4. Computational simulation of the flow dynamic field in a porous ureteric stent.Medical & biological engineering & computing · 2022
    Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Tal Amitay-RosenDepartment of Physical Chemistry, Institute for Biological Research, 7410001, Ness-Ziona, Israel.
Alon NissanDepartment of Earth and Planetary Sciences, Weizmann Institute of Science, 7610001, Rehovot, Israel.
Yaniv ShiloDepartment of Urology, Kaplan Medical Center, 7661041, Rehovot, Israel.
Ishai DrorDepartment of Earth and Planetary Sciences, Weizmann Institute of Science, 7610001, Rehovot, Israel.
Brian BerkowitzDepartment of Earth and Planetary Sciences, Weizmann Institute of Science, 7610001, Rehovot, Israel. brian.berkowitz@weizmann.ac.il.ORCID http://orcid.org/0000-0003-3078-1859
Weizmann Institute of Science · ILIsrael Institute for Biological Research · ILKaplan Medical Center · IL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo quantify the occurrence of stent failure and the dynamic behavior of urine flow in ureter-stent systems, including the relative flow in the ureter and stent lumina, subject to various degrees of ureter and stent blockage.

methodsNumerical simulations based on computational fluid dynamics (CFD) were used to quantify urine flow behavior in stented ureters, in the presence of extrinsic ureteral obstruction (EUO) and stent occlusions. Two stented ureter configurations were considered, one with circumferential occlusion of the ureter and the second with pressure on one side of the ureter wall. The pressure within the renal unit for different degrees of ureter closure and stent lumen occlusion was determined systematically. Onset of stent failure and the distribution of urine flow between stent and ureter lumina were determined.

resultsIn the case of EUO completely encircling the ureter, causing 100% obstruction of the ureter lumen, pressure in the renal unit is essentially unaffected until the stent lumen reaches ~ 90% occlusion, and fails only with > 95% occlusion. Occlusions of 50% in stent side holes in the vicinity of the EUO only alter local flow patterns but have no significant influence on renal unit pressure. For EUO deforming and compressing the ureter from one side, with ~ 50% reduction in ureter lumen, urine drainage proceeds with negligible increase in renal pressure even with 100% occlusion in the stent lumen.

conclusionCFD simulations show that stent failure under EUO tends to occur suddenly, only when both ureter and stent lumina become almost fully blocked.

Indexed as

StentsComputer SimulationHumansProsthesis FailureTreatment FailureUreterUreteral ObstructionUrineUrodynamicsComputational fluid dynamicsNumerical simulationRenal unit pressureStent failureStent incrustation

Identifiers

PMID33595820
OpenAlexW3129725713

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.