Evidence map›Paper›PMID 33595478›Full record

ArticleIndian journal of ophthalmology2021

Comparison of three newer generation freely available intraocular lens power calculation formulae across all axial lengths.

Zain Irfan Khatib, Suhas S Haldipurkar, Vijay Shetty, Harsha Dahake, Pranoti Nagvekar, Priyanka Kashelkar

Abstract read
In one paragraph

Article in Indian journal of ophthalmology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Zain Irfan KhatibLaxmi Eye Institute, Panvel, Navi Mumbai, Maharashtra, India.
Suhas S HaldipurkarLaxmi Eye Institute, Panvel, Navi Mumbai, Maharashtra, India.
Vijay ShettyLaxmi Eye Institute, Panvel, Navi Mumbai, Maharashtra, India.
Harsha DahakeLaxmi Eye Institute, Panvel, Navi Mumbai, Maharashtra, India.
Pranoti NagvekarLaxmi Eye Institute, Panvel, Navi Mumbai, Maharashtra, India.
Priyanka KashelkarLaxmi Eye Institute, Panvel, Navi Mumbai, Maharashtra, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The aim of this study is to evaluate the accuracy of three newer generation formulae (Barrett Universal II, EVO, Hill-RBF 2.0) for calculation of power of two standard IOLs-the Acrysof IQ and Tecnis ZCB00 across all axial lengths. Methods: In this retrospective series, 206 eyes of 206 patients, operated for cataract surgery with above two IOLs over the last 6 months, were included in the study. Preoperative biometry measurements were obtained from LenstarLS900. By using recommended lens constants, the mean error for each formula was calculated and compared. Then, the optimized IOL constants were calculated to reduce the mean error to zero. Mean and median absolute errors were calculated for all eyes and separately for short (AL<22.5 mm), medium (22.5-24.5 mm), and long eyes (>24.5 mm). Absolute errors and percentages of eyes within prediction errors of ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 D were compared. Results: Prediction error with using recommended lens constants was significantly lower in the Barrett Universal II formula as compared to the other two formulae. However, after optimizing lens constants, there were no significant differences in the absolute errors between the three formulae. The formulae ranked by mean absolute error were as follows: Barrett Universal II (0.304 D), EVO (0.317 D), and Hill-RBF (0.322) D. There were no significant differences between absolute errors in the three formulae in each of the short-, medium-, and long-eye subgroups. Conclusion: With proper lens constant optimization, the Barrett Universal II, EVO, and Hill-RBF 2.0 formulae were equally accurate in predicting IOL power across the entire range of axial lengths.

Indexed as

Lenses, IntraocularPhacoemulsificationBiometryHumansLens Implantation, IntraocularOptics and PhotonicsRefraction, OcularRetrospective StudiesBarrettEVOHill-RBF

Identifiers

PMID33595478
PMCPMC7942088

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.