Evidence map›Paper›PMID 33594993›Full record

ArticlePhysics in medicine and biology2021

Deformable motion compensation for interventional cone-beam CT.

S Capostagno, A Sisniega, J W Stayman, T Ehtiati, C R Weiss, J H Siewerdsen

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Article
  2. Forward and Back Projectors for Gradient-based Rigid Motion Estimation in X-ray Imaging.Proceedings of SPIE--the International Society for Optical Engineering · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Contrast-enhanced photon-counting micro-CT of tumor xenograft models.bioRxiv : the preprint server for biology · 2024
    Article
  9. Article
  10. Article
  11. Simulation of Random Deformable Motion in Soft-Tissue Cone-Beam CT with Learned Models.Proceedings of SPIE--the International Society for Optical Engineering · 2022
    Article
  12. Context-Aware, Reference-Free Local Motion Metric for CBCT Deformable Motion Compensation.Proceedings of SPIE--the International Society for Optical Engineering · 2022
    Article
  13. Article
  14. Article
  15. Targeted Deformable Motion Compensation for Vascular Interventional Cone-Beam CT Imaging.Proceedings of SPIE--the International Society for Optical Engineering
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

S CapostagnoDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, United States of America.
A SisniegaDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, United States of America.ORCID 0000-0003-2030-2711
J W StaymanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, United States of America.
T EhtiatiSiemens Medical Solutions USA, Inc., Imaging & Therapy Systems, Hoffman Estates, IL 60192, United States of America.
C R WeissDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, United States of America.
J H SiewerdsenDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, United States of America.ORCID 0000-0001-6644-1317

Funding

Intraoperative Imaging for Guidance, Patient Safety, and OR Quality AssuranceR01EB017226 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI SIEWERDSEN, JEFFREY H · 2014 to 2017
$2.1M
NIBIB NIH HHS R01 EB017226
6 · The paper itself

Abstract

Image-guided therapies in the abdomen and pelvis are often hindered by motion artifacts in cone-beam CT (CBCT) arising from complex, non-periodic, deformable organ motion during long scan times (5-30 s). We propose a deformable image-based motion compensation method to address these challenges and improve CBCT guidance. Motion compensation is achieved by selecting a set of small regions of interest in the uncompensated image to minimize a cost function consisting of an autofocus objective and spatiotemporal regularization penalties. Motion trajectories are estimated using an iterative optimization algorithm (CMA-ES) and used to interpolate a 4D spatiotemporal motion vector field. The motion-compensated image is reconstructed using a modified filtered backprojection approach. Being image-based, the method does not require additional input besides the raw CBCT projection data and system geometry that are used for image reconstruction. Experimental studies investigated: (1) various autofocus objective functions, analyzed using a digital phantom with a range of sinusoidal motion magnitude (4, 8, 12, 16, 20 mm); (2) spatiotemporal regularization, studied using a CT dataset from The Cancer Imaging Archive with deformable sinusoidal motion of variable magnitude (10, 15, 20, 25 mm); and (3) performance in complex anatomy, evaluated in cadavers undergoing simple and complex motion imaged on a CBCT-capable mobile C-arm system (Cios Spin 3D, Siemens Healthineers, Forchheim, Germany). Gradient entropy was found to be the best autofocus objective for soft-tissue CBCT, increasing structural similarity (SSIM) by 42%-92% over the range of motion magnitudes investigated. The optimal temporal regularization strength was found to vary widely (0.5-5 mm

Indexed as

Cone-Beam Computed TomographyOrgan MotionAlgorithmsArtifactsHumansImage Processing, Computer-AssistedPhantoms, ImagingTime Factors

Identifiers

PMID33594993
PMCPMC13131970

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.