ArticleStrahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]2021
Improving dose delivery accuracy with EPID in vivo dosimetry: results from a multicenter study.
Article in Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al], 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed, 24 citations in OpenAlex.
- In vivo dosimetry using an electronic portal imaging device for pediatric myeloablative Total body irradiation with volumetric modulated arc therapy.Physics and imaging in radiation oncology · 2026Article
- In-vivo dosimetry using electronic portal imaging in online-adaptive radiotherapy for rectal cancer.Physics and imaging in radiation oncology · 2026Article
- Quantitative evaluation of the effect of anatomical changes on the results of in vivo dosimetry during radiation therapy in the thoracic region.Journal of applied clinical medical physics · 2026Article
- Determining optimal transit dosimetry gamma parameter values for the detection of failure modes using receiver operating curve analysis.Journal of applied clinical medical physics · 2026Article
- CycleGan-based kV-to-MV image translation for potential in vivo dosimetry application: concept proposal and cross-institutional validation.BMC medical imaging · 2025Article
- Deep learning-based 3D dose reconstruction for intensity modulated radiation therapy using electronic portal imaging devices.Journal of applied clinical medical physics · 2025Article
- A commissioning protocol for portal imaging-based radiotherapy in vivo dosimetry systems.Physics and imaging in radiation oncology · 2024Article
- In vivo EPID-based daily treatment error identification for volumetric-modulated arc therapy in head and neck cancers with a hierarchical convolutional neural network: a feasibility study.Physical and engineering sciences in medicine · 2024Article
- Validation of an in vivo transit dosimetry algorithm using Monte Carlo simulations and ionization chamber measurements.Journal of applied clinical medical physics · 2024Article
- Robustness analysis of surface-guided DIBH left breast radiotherapy: personalized dosimetric effect of real intrafractional motion within the beam gating thresholds.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2024Article
- The role of EPID in vivo dosimetry in the risk management of stereotactic lung treatments.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2023Article
- Gamma passing rates of daily EPID transit images correlate to PTV coverage for breast cancer IMRT treatment plans.Journal of applied clinical medical physics · 2023Article
- Performance of a Full-Scale Upstream MAPS-Based Verification Device for Radiotherapy.Sensors (Basel, Switzerland) · 2023Article
- Assessing the impact of adaptations to the clinical workflow in radiotherapy using transit in vivo dosimetry.Physics and imaging in radiation oncology · 2023Article
- Comparing treatment uncertainty for ultra- vs. standard-hypofractionated breast radiation therapy based on in-vivo dosimetry.Physics and imaging in radiation oncology · 2022Article
- Evaluation of Daily CT for EPID-Based TransitFrontiers in oncology · 2021Article
- Dose Characteristics of a Deep Learning Model for EPID-basedJournal of medical physicsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
17 authors at 9 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo investigate critical aspects and effectiveness of in vivo dosimetry (IVD) tests obtained by an electronic portal imaging device (EPID) in a multicenter and multisystem context. MATERIALS AND
methodsEight centers with three commercial systems-SoftDiso (SD, Best Medical Italy, Chianciano, Italy), Dosimetry Check (DC, Math Resolution, LCC), and PerFRACTION (PF, Sun Nuclear Corporation, SNC, Melbourne, FL)-collected IVD results for a total of 2002 patients and 32,276 tests. Data are summarized for IVD software, radiotherapy technique, and anatomical site. Every center reported the number of patients and tests analyzed, and the percentage of tests outside of the tolerance level (OTL%). OTL% was categorized as being due to incorrect patient setup, incorrect use of immobilization devices, incorrect dose computation, anatomical variations, and unknown causes.
resultsThe three systems use different approaches and customized alert indices, based on local protocols. For Volumetric Modulated Arc Therapy (VMAT) treatments OTL% mean values were up to 8.9% for SD, 18.0% for DC, and 16.0% for PF. Errors due to "anatomical variations" for head and neck were up to 9.0% for SD and DC and 8.0% for PF systems, while for abdomen and pelvis/prostate treatments were up to 9%, 17.0%, and 9.0% for SD, DC, and PF, respectively. The comparison among techniques gave 3% for Stereotactic Body Radiation Therapy, 7.0% (range 4.7-8.9%) for VMAT, 10.4% (range 7.0-12.2%) for Intensity Modulated Radiation Therapy, and 13.2% (range 8.8-21.0%) for 3D Conformal Radiation Therapy.
conclusionThe results obtained with different IVD software and among centers were consistent and showed an acceptable homogeneity. EPID IVD was effective in intercepting important errors.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials