Evidence map›Paper›PMID 33594456›Full record

ArticleInternational journal of legal medicine2021

Validation of forensic facial comparison by morphological analysis in photographic and CCTV samples.

Nicholas Bacci, Tobias M R Houlton, Nanette Briers, Maryna Steyn

Abstract readValidation Study
PubMed Publisher
In one paragraph

Article in International journal of legal medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Effect of genetic variants inForensic sciences research · 2023
    Article
  9. Article
  10. Review
  11. Article
  12. Morphology of facial aging: a shape-based quantification.Romanian journal of morphology and embryology = Revue roumaine de morphologie et embryologie
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Nicholas BacciHuman Variation and Identification Research Unit, School of Anatomical Sciences, University of the Witwatersrand, 7 York Road, Parktown, Johannesburg, 2193, South Africa. nicholas.bacci@wits.ac.za.ORCID http://orcid.org/0000-0001-6858-7598
Tobias M R HoultonHuman Variation and Identification Research Unit, School of Anatomical Sciences, University of the Witwatersrand, 7 York Road, Parktown, Johannesburg, 2193, South Africa.ORCID https://orcid.org/0000-0003-1215-0869
Nanette BriersHuman Variation and Identification Research Unit, School of Anatomical Sciences, University of the Witwatersrand, 7 York Road, Parktown, Johannesburg, 2193, South Africa.ORCID https://orcid.org/0000-0002-8544-6049
Maryna SteynHuman Variation and Identification Research Unit, School of Anatomical Sciences, University of the Witwatersrand, 7 York Road, Parktown, Johannesburg, 2193, South Africa.ORCID https://orcid.org/0000-0002-0215-9723

Funding

J.J.J. Smieszeck Fellowship N/ASouth African National Research Foundation 11858South African National Research Foundation CSUR160425163022; UID: 106031
6 · The paper itself

Abstract

Between the ever-increasing availability of surveillance evidence and expert-based forensic facial comparison being considered admissible in court, confirming its validity is paramount. Facial comparison is most commonly conducted using morphological analysis (MA), a largely untested feature-based approach. This study aimed at validating the current recommended practice of MA in both standardised and suboptimal surveillance samples. Face pools of 175 South African males were compiled with a series of facial photographs, using images from the Wits Face Database. The first 75 face pools consisted of wildtype (unstandardised) high-quality target photographs, while the remaining 100 face pools consisted of suboptimal closed-circuit television (CCTV) target images. Target images were compared to high-quality standardised photographs. Face pools were analysed using the Facial Identification Scientific Working Group's guidelines and feature list. Confusion matrices were used to determine the performance of MA in each cohort. MA was found highly accurate (chance-corrected accuracy (CCA): 99.1%) and reliable (κ = 0.921) in the photographic sample and less accurate (CCA: 82.6%) and reliable (κ = 0.743), in the CCTV sample. Higher false-positive and false-negative rates were noted for the CCTV sample, with the majority of errors resulting in false-negative outcomes. The decreased performance in the CCTV sample was attributed to various factors including image quality, angle of recording and lighting. Other studies testing facial comparison identified lower accuracies and reliability across various conditions. Better performance was found here and in other studies that included some form of facial feature list, reinforcing the importance of using a systematic facial feature list.

Indexed as

Facial RecognitionPhotographyTelevisionVideo RecordingAdultDatabases, FactualForensic SciencesGuidelines as TopicHumansMalePredictive Value of TestsSensitivity and SpecificitySouth AfricaCCTVFace mappingFacial identificationFISWGForensic facial comparisonMorphological analysis

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.