Evidence map›Paper›PMID 33591449›Full record

ArticleSurgical endoscopy2022

Versatility and clinical effectiveness of a synthetic sealing hemostatic patch as alternative to parenchyma suturing in laparoscopic partial nephrectomy.

Eva Erne, Stephan Kruck, Tilman Todenhoefer, Stefan Aufderklamm, Bastian Amend, Jens Bedke, Arnulf Stenzl, Steffen Rausch

Open access · hybridAbstract read
In one paragraph

Article in Surgical endoscopy, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 12 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Eva ErneDepartment of Urology, Medical Faculty and University Hospital, Eberhard-Karls-University Tuebingen, Tübingen, Germany.
Stephan KruckDepartment of Urology, Medical Faculty and University Hospital, Eberhard-Karls-University Tuebingen, Tübingen, Germany.
Tilman TodenhoeferDepartment of Urology, Medical Faculty and University Hospital, Eberhard-Karls-University Tuebingen, Tübingen, Germany.
Stefan AufderklammDepartment of Urology, Medical Faculty and University Hospital, Eberhard-Karls-University Tuebingen, Tübingen, Germany.
Bastian AmendDepartment of Urology, Medical Faculty and University Hospital, Eberhard-Karls-University Tuebingen, Tübingen, Germany.
Jens BedkeDepartment of Urology, Medical Faculty and University Hospital, Eberhard-Karls-University Tuebingen, Tübingen, Germany.
Arnulf StenzlDepartment of Urology, Medical Faculty and University Hospital, Eberhard-Karls-University Tuebingen, Tübingen, Germany.
Steffen RauschDepartment of Urology, Medical Faculty and University Hospital, Eberhard-Karls-University Tuebingen, Tübingen, Germany. steffen.rausch@med.uni-tuebingen.de.ORCID 0000-0002-6398-8701
University of Tübingen · DESiloah St. Trudpert Klinikum · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundImprovements in laparoscopic partial nephrectomy (LPN) in order to minimize perioperative warm ischemia time (WIT), complications, and consequently patient outcome are desirable. Veriset™ is a ready-to-use hemostatic patch of absorbable oxidized cellulose and hydrogel components that has earlier been implemented in vascular and hepatic surgery. We report our experience using this device in LPN.

methodsPatients with a solitary malignant renal mass suspicious for renal cancer underwent LPN with either the use of Veriset™ hemostatic patch (n = 40) or conventional suture technique (n = 40). Patient characteristics, operation time and WIT, postoperative course and complications were recorded retrospectively. Tumor complexity was calculated according to the R.E.N.A.L. score. Outcome was determined according to the "trifecta" criteria (negative surgical margin, WIT < 25 min, no complications within 30 days).

resultsNo significant differences with regard to clinical parameters and median R.E.N.A.L. score (6) were observed between both groups. Operation time (mean 127.1 min vs. 162. 8 min; p = 0.001) and WIT were both lower in the Veriset™ group (14.6 min vs. 20.6 min; p = 0.01). No differences in surgical margins (p = 0.602) and overall complication rates at 30 (p = 0.599) and 90 days (p = 0.611) postoperatively were noticed. The surgical outcome according to "trifecta" was achieved in 65% of patients using Veriset™ and in 57.5% of patients by suture closure, respectively.

conclusionThe hemostatic Veriset™ patch can successfully be implemented in LPN. Handling and application appear favorable, thereby reducing operation time and WIT. The present results suggest that the device may represent an alternative to parenchyma suturing in LPN.

Indexed as

HemostaticsKidney NeoplasmsLaparoscopyHumansNephrectomyRetrospective StudiesSuturesTreatment OutcomeHemostaticsComplicationHemopatchHemostasisLaparoscopic partial nephrectomyVeriset

Identifiers

PMID33591449
PMCPMC8741715
OpenAlexW3133061346

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.