Evidence map›Paper›PMID 33590821›Full record

Trial reportJournal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine2021

Validation of the Withings Sleep Analyzer, an under-the-mattress device for the detection of moderate-severe sleep apnea syndrome.

Paul Edouard, David Campo, Pierre Bartet, Rui-Yi Yang, Marie Bruyneel, Gabriel Roisman, Pierre Escourrou

2 registry-linked trialsOpen access · bronzeAbstract readClinical Trial
In one paragraph

Trial report in Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 69 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
69citing papers in PubMed, 2 pooled it
9.7field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04234828 active not recruitingnot on this map

Validation of the Diagnostic Performance of the Withings Sleep Device in Detecting Sleep Apnea Syndrome

TypeobservationalSponsorWithingsRan2019 to 2026Enrolled200ConditionsSleep Apnea Syndromes
NCT05742191 unknown statusnot on this mapstarted 2023, after this paper: background citation

The Effect of Daylight Saving Time Transitions on Sleep and Migraine Headaches.

TypeobservationalSponsorOSF Healthcare SystemRan2023 to 2023Enrolled50ConditionsEpisodic MigraineArmsDaylight Savings time transitions
3 · Its place in the literature

Who cites it

69 citing papers in PubMed, 2 syntheses or guidelines pooled it, 129 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article

9 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 3 countries.

Paul EdouardWithings, Issy-les-Moulineaux, France.
David CampoWithings, Issy-les-Moulineaux, France.
Pierre BartetWithings, Issy-les-Moulineaux, France.
Rui-Yi YangWithings, Issy-les-Moulineaux, France.
Marie BruyneelChest Service, Saint-Pierre University Hospital, Brussels, Belgium.
Gabriel RoismanAP-HP, Sleep Medicine Department, Antoine-Béclère Hospital, Clamart, France.
Pierre EscourrouCIS, Paris, France.
Assistance Publique – Hôpitaux de Paris · FRCentre Hospitalier Universitaire de Saint-Pierre · BEIn-Q-Tel · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

STUDY

objectivesTo assess the diagnostic performance of a nonintrusive device placed under the mattress to detect sleep apnea syndrome.

methodsOne hundred eighteen patients suspected to have obstructive sleep apnea syndrome completed a night at a sleep clinic with a simultaneous polysomnography (PSG) and recording with the Withings Sleep Analyzers. PSG nights were scored twice: first as simple polygraphy, then as PSG.

resultsAverage (standard deviation) apnea-hypopnea index from PSG was 31.2 events/h (25.0) and 32.8 events/h (29.9) according to the Withings Sleep Analyzers. The mean absolute error was 9.5 events/h. The sensitivity, specificity, and area under the receiver operating characteristic curve at thresholds of apnea-hypopnea index ≥ 15 events/h were, respectively, sensitivity (Se)

conclusionsWithings Sleep Analyzers accurately detect moderate-severe sleep apnea syndrome in patients suspected of sleep apnea syndrome. This simple and automated approach could be of great clinical value given the high prevalence of sleep apnea syndrome in the general population. CLINICAL

trial registrationRegistry: ClinicalTrials.gov; Name: Validation of Withings Sleep for the Detection of Sleep Apnea Syndrome; URL: https://clinicaltrials.gov/ct2/show/NCT04234828; Identifier: NCT04234828.

Indexed as

Sleep Apnea, ObstructiveSleep Apnea SyndromesHumansPolysomnographyROC CurveSleepdeep learninge-healthhome monitoringpolygraphypolysomnographyscreeningsleep apneaunder-the-mattress sensor

Identifiers

PMID33590821
PMCPMC8314651
OpenAlexW3131624026

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.