Comparison of different CT metal artifact reduction strategies for standard titanium and carbon-fiber reinforced polymer implants in sheep cadavers.

Florian A Huber, Kai Sprengel, Lydia Müller, Laura C Graf, Georg Osterhoff, Roman Guggenberger

Open access · goldAbstract readComparative Study
In one paragraph

Article in BMC medical imaging, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 28 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Personalized Approaches to Spine Surgery.International journal of spine surgery · 2024
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Florian A HuberInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich, Faculty of Medicine, University of Zurich, Raemistrasse 100, 8091, Zurich, Switzerland. florian.huber@usz.ch.ORCID 0000-0001-6317-4815
Kai SprengelDepartment of Trauma, University Hospital Zurich, Faculty of Medicine, University of Zurich, 8091, Zurich, Switzerland.ORCID 0000-0001-5921-8272
Lydia MüllerInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich, Faculty of Medicine, University of Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.ORCID 0000-0001-9544-121X
Laura C GrafInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich, Faculty of Medicine, University of Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.ORCID 0000-0001-8600-1044
Georg OsterhoffDepartment of Trauma, University Hospital Zurich, Faculty of Medicine, University of Zurich, 8091, Zurich, Switzerland.ORCID 0000-0001-5051-0998
Roman GuggenbergerInstitute of Diagnostic and Interventional Radiology, University Hospital Zurich, Faculty of Medicine, University of Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.ORCID 0000-0002-5903-2248
University of Zurich · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCT artifacts induced by orthopedic implants can limit image quality and diagnostic yield. As a number of different strategies to reduce artifact extent exist, the aim of this study was to systematically compare ex vivo the impact of different CT metal artifact reduction (MAR) strategies on spine implants made of either standard titanium or carbon-fiber-reinforced-polyetheretherketone (CFR-PEEK).

methodsSpine surgeons fluoroscopically-guided prepared six sheep spine cadavers with pedicle screws and rods of either titanium or CFR-PEEK. Samples were subjected to single- and dual-energy (DE) CT-imaging. Different tube voltages (80, DE mixed, 120 and tin-filtered 150 kVp) at comparable radiation dose and iterative reconstruction versus monoenergetic extrapolation (ME) techniques were compared. Also, the influence of image reconstruction kernels (soft vs. bone tissue) was investigated. Qualitative (Likert scores) and quantitative parameters (attenuation changes induced by implant artifact, implant diameter and image noise) were evaluated by two independent radiologists. Artifact degree of different MAR-strategies and implant materials were compared by multiple ANOVA analysis.

resultsCFR-PEEK implants induced markedly less artifacts than standard titanium implants (p < .001). This effect was substantially larger than any other tested MAR technique. Reconstruction algorithms had small impact in CFR-PEEK implants and differed significantly in MAR efficiency (p < .001) with best MAR performance for DECT ME 130 keV (bone kernel). Significant differences in image noise between reconstruction kernels were seen (p < .001) with minor impact on artifact degree.

conclusionsCFR-PEEK spine implants induce significantly less artifacts than standard titanium compositions with higher MAR efficiency than any alternate scanning or image reconstruction strategy. DECT ME 130 keV image reconstructions showed least metal artifacts. Reconstruction kernels primarily modulate image noise with minor impact on artifact degree.

Indexed as

ArtifactsBenzophenonesImage Processing, Computer-AssistedPolymersProstheses and ImplantsTitaniumAnimalsCarbon FiberFemaleMultidetector Computed TomographyProsthesis DesignSheepSpineBenzophenonesCarbon FiberpolyetheretherketonePolymersTitaniumArtifactsDiagnostic imagingImage reconstructionMultidetector computed tomographyPedicle screwsPEEK

Identifiers

PMID33588781
PMCPMC7885519
OpenAlexW3129461124

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.