ReviewFrontiers in pediatrics2020
Non-invasive Cardiac Output Monitoring in Neonates.
Review in Frontiers in pediatrics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 1 synthesis or guideline pooled it, 36 citations in OpenAlex.
- A recommendation for the use of electrical biosensing technology in neonatology.Pediatric research · 2025Guideline
- Association between 24-hour urine output during early non-invasive ventilation and short-term adverse outcomes in late preterm infants: a retrospective cohort study.Translational pediatrics · 2026Article
- The Longitudinal Physiological Reference Values of Middle Cerebral Artery Blood Flow Velocity in Extremely Preterm Infants: A Study Utilizing Multimodal Cerebral Hemodynamic Monitors.Children (Basel, Switzerland) · 2026Article
- Minute-by-minute systemic hemodynamic responses to packed red blood cell transfusion in extremely low gestational age neonates: a prospective cohort study.Pediatric research · 2026Article
- HYPER-HIE Phenotype: Postrewarming Systemic Hypertension Following Hypoxic-Ischemic Encephalopathy-A Case Report and Mechanistic Review.Case reports in pediatrics · 2026Article
- Article
- Cerebral Near-Infrared Spectroscopy and Electrical Cardiometry During Endotracheal Suction in Ventilated Infants Following Surgery: A Feasibility Study.Life (Basel, Switzerland) · 2025Article
- Neonatal reference values and nomograms of systemic vascular resistances estimated with electrical cardiometry.Journal of perinatology : official journal of the California Perinatal Association · 2025Article
- Thoracic fluid content (TFC) using electrical cardiometry versus lung ultrasound in the diagnosis of transient tachypnea of newborn.European journal of pediatrics · 2024Observational
- Electrical Cardiometry during transition and short-term outcome in very preterm infants: a prospective observational study.European journal of pediatrics · 2024Observational
- Ultra-Wideband Radar for Simultaneous and Unobtrusive Monitoring of Respiratory and Heart Rates in Early Childhood: A Deep Transfer Learning Approach.Sensors (Basel, Switzerland) · 2023Article
- Evaluation of the Hypotensive Preterm Infant: Evidence-Based Practice at the Bedside?Children (Basel, Switzerland) · 2023Review
- Automatic Prediction of Paediatric Cardiac Output From Echocardiograms Using Deep Learning Models.CJC pediatric and congenital heart disease · 2023Article
- Time series analysis of non-invasive hemodynamic monitoring data in neonates with hypoxic-ischemic encephalopathy.Frontiers in pediatrics · 2023Article
- Non-invasive continuous cardiac output monitoring in infants with hypoxic ischaemic encephalopathy.Journal of perinatology : official journal of the California Perinatal Association · 2022Observational
- [Hemodynamic monitoring in pediatric anesthesia].Die Anaesthesiologie · 2022Review
- Non-invasive Cardiac Output Monitoring and Assessment of Fluid Responsiveness in Children With Shock in the Emergency Department.Frontiers in pediatrics · 2022Article
- Neonatal Impedance Cardiography in Asphyxiated Piglets-A Feasibility Study.Frontiers in pediatrics · 2022Article
- In-Silico Evaluation of Anthropomorphic Measurement Variations on Electrical Cardiometry in Neonates.Children (Basel, Switzerland) · 2021Article
- Cerebral Oximetry in Preterm Infants-To Use or Not to Use, That Is the Question.Frontiers in pediatrics · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Circulatory monitoring is currently limited to heart rate and blood pressure assessment in the majority of neonatal units globally. Non-invasive cardiac output monitoring (NiCO) in term and preterm neonates is increasing, where it has the potential to enhance our understanding and management of overall circulatory status. In this narrative review, we summarized 33 studies including almost 2,000 term and preterm neonates. The majority of studies evaluated interchangeability with echocardiography. Studies were performed in various clinical settings including the delivery room, patent ductus arteriosus assessment, patient positioning, red blood cell transfusion, and therapeutic hypothermia for hypoxic ischemic encephalopathy. This review presents an overview of NiCO in neonatal care, focusing on technical and practical aspects as well as current available evidence. We discuss potential goals for future research.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.