ArticleAnatolian journal of cardiology2021
Ultrathin (60 μm), ultralong (≥40 mm) sirolimus-eluting stent: study of clinical and safety profiles among real-world patients.
Article in Anatolian journal of cardiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Clinical safety and performance of a biodegradable polymer-coated sirolimus-eluting stent in an all-comers population: results from the S-FLEX Russia registry.AsiaIntervention · 2025Article
- Article
- Article
- Twelve months clinical outcomes of ultrathin strut sirolimus-eluting stent in real-world Indian patients with coronary artery disease.American journal of cardiovascular disease · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveAlthough thin-strut drug-eluting stents (DES) with a more flexible design are easily obtainable, data regarding using ultralong DES (≥40 mm) for long coronary lesions are limited in the literature. Therefore, the current study assessed the safety and efficacy of an ultralong (≥40 mm) and ultrathin (60 μm) biodegradable polymer-coated sirolimus-eluting stent (SES), Supralimus Grace, with a unique Long Dual Z-link (LDZ-link) design (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) in real-world patients with long coronary lesions.
methodsThe assigned stents were implanted in 684 patients. The primary endpoint was target lesion failure (TLF), which is a composite of cardiovascular death, target vessel myocardial infarction (MI), and target lesion revascularization (TLR), whereas periprocedural secondary endpoints included device failure (failure of stent delivery, change of stent, and stent fracture) and patient-oriented composite endpoint (POCE), which is a composite of all deaths, any MI, and any revascularization, and stent thrombosis (ST). These outcomes were analyzed at one-year follow-up and during the procedure.
resultsThe patients' mean age was 52.7±15.9 years; 537 (78.5%) were males. 626 (91.5%) patients suffered from acute coronary syndrome and 58 (8.5%) patients from chronic coronary syndrome (CSS). 989 lesions were removed. The mean numbers of lesions and stents implanted per patient were 1.3±0.2 mm and 1.4±0.3 mm, respectively. TLF occurred in 42 (6.1%) as a result of cardiac death, target vessel MI, and TLR in 9 (1.3%), 20 (2.9%), and 13 (1.9%) patients, respectively. POCE was observed in 131 patients (19.1%) at one-year follow-up, mainly in 63 (9.2%) patients because of any revascularization. Stent failure was seen in 21 patients (3.1%) as a result of delivery failure (2.2%), edge dissection (0.8%), and fracture (0.1%). Definite and probable ST were observed in 8 (1.1%) and 9 (1.3%) patients, respectively.
conclusionUltralong (≥40 mm), ultrathin (60 μm) Supralimus Grace stent can be safely implanted in vessels having long and multiple lesions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.