Evidence map›Paper›PMID 33582865›Full record

ArticleArchives of orthopaedic and trauma surgery2021

Can a simple iPad app improve C-arm based component position in anterior THA?

Ulrich Bechler, Bernhard Springer, Kilian Rueckl, Tim Rolvien, Friedrich Boettner

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 6 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Ulrich BechlerHospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
Bernhard SpringerHospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
Kilian RuecklHospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
Tim RolvienDepartment of Orthopedics, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20251, Hamburg, Germany.
Friedrich BoettnerHospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA. boettnerf@hss.edu.ORCID http://orcid.org/0000-0002-7906-9486
Hospital for Special Surgery · USUniversität Hamburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionCorrect acetabular component positioning improves hip biomechanics, impingement free range of motion and may lead to a reduced risk of postoperative dislocation. The C-arm is a simple and cost-effective tool for THA in a supine position, however, evaluation of the images can be challenging due to parallax. The current study aimed to investigate whether a software app-based measurement technique can control acetabular component position and leg length in anterior THA. MATERIALS AND

methodsNinety-three patients with end-stage osteoarthritis aged 65.2 ± 9.6 years (range 30-86 years) were included in this prospective study. All patients underwent direct anterior THA using a Hana orthopedic surgery table. C-arm imaging and an iPad software app were used to determine intraoperative acetabular anteversion, inclination and leg length discrepancy. The app provides a measuring tool that is applied to intraoperative c-arm images. The intraoperative measurements were compared to the measurements of standard postoperative AP-pelvis radiographs.

resultsIntraoperative software app-based anteversion measurements averaged 20.5° (range 16.0° to 24.0°) compared to 20.9° (range 14.7° to 25.6°) postoperatively. Mean intraoperative inclination was 40.5° (range 35° to 48°) compared to postoperative 40.7° (range 35° to 49°). Mean intraoperative leg length discrepancy was 0.9 mm (range - 4-5 mm) compared to postoperative 0.6 mm (range - 5-6 mm). A strong Pearson's correlation was observed between the intraoperative and postoperative measurements for anteversion (r = .701; P < .0001), inclination (r = .816; P < .0001) and leg length discrepancy (r = .542; P < .0001).

conclusionsThe software app used in the current study allowed for a simple and accurate measurement of intraoperative cup position and leg length in direct anterior THA.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisMobile ApplicationsAcetabulumFluoroscopyHumansProspective StudiesRetrospective StudiesAcetabular componentAnterior approachCup positionIntraoperative fluoroscopySoftware appTotal hip arthroplasty

Identifiers

PMID33582865
OpenAlexW3133459623

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.