Evidence map›Paper›PMID 33580119›Full record

ArticleScientific reports2021

Area efficient folded undecimator based ECG detector.

A Uma, P Kalpana

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

A UmaPSG College of Technology, Coimbatore, Tamil Nadu, India. umavithy22@yahoo.com.
P KalpanaPSG College of Technology, Coimbatore, Tamil Nadu, India.
PSG INSTITUTE OF TECHNOLOGY AND APPLIED RESEARCH · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents an area-efficient folded wavelet filter-based Electrocardiogram (ECG) detector for cardiac pacemakers. The modified folded undecimator based detector consists of Wavelet Filter Bank, QRS complex detector with Generalized Likelihood Ratio Test (GLRT) block and noise detector. A high-level transformation technique such as folding transformation and Cutset retiming are applied to the GLRT block in order to reduce the silicon area. Folding is a high-level transformation applied at the architectural level to enhance the performance of DSP architectures. It reduces the number of adders, multipliers and delay elements in the architecture. The Cutset retiming reduces clock period of the architecture by changing position of delay elements in the critical path. The folding transformation and cutset retiming implement the functional blocks of the GLRT circuit with minimum hardware. The modified folded ECG detector is tested for short term and long-term MIT-BIH databases. The results show that the modified folded undecimator detector has hardware savings and achieves sensitivity of 99.95%, positive prediction of 99.97% and Detection Error Rate (DER) of 0.061. The folded GLRT block architecture is synthesized with FPGA Zed board XC7Z010CLG484-1. Results show that the device utilization and power consumption are lesser than the conventional GLRT structure.

Identifiers

PMID33580119
PMCPMC7881094
OpenAlexW3128657423

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.