Evidence map›Paper›PMID 33578643›Full record

ArticleDiagnostics (Basel, Switzerland)2021

Potential for Radiation Dose Reduction in Dual-Source Computed Tomography of the Lung in the Pediatric and Adolescent Population Compared to Digital Radiography.

Matthias Wetzl, Matthias Stefan May, Daniel Weinmann, Matthias Hammon, Markus Kopp, Renate Ruppel, Regina Trollmann, Joachim Woelfle, Michael Uder, Oliver Rompel

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Matthias WetzlDepartment of Radiology, University Hospital Erlangen, 91054 Erlangen, Germany.ORCID 0000-0001-9980-9528
Matthias Stefan MayDepartment of Radiology, University Hospital Erlangen, 91054 Erlangen, Germany.ORCID 0000-0002-2540-850X
Daniel WeinmannDepartment of Radiology, University Hospital Erlangen, 91054 Erlangen, Germany.
Matthias HammonDepartment of Radiology, University Hospital Erlangen, 91054 Erlangen, Germany.ORCID 0000-0002-3937-2763
Markus KoppDepartment of Radiology, University Hospital Erlangen, 91054 Erlangen, Germany.
Renate RuppelDepartment of Pediatrics and Adolescent Medicine, University Hospital Erlangen, 91054 Erlangen, Germany.
Regina TrollmannDepartment of Pediatrics and Adolescent Medicine, University Hospital Erlangen, 91054 Erlangen, Germany.ORCID 0000-0001-6031-8537
Joachim WoelfleDepartment of Pediatrics and Adolescent Medicine, University Hospital Erlangen, 91054 Erlangen, Germany.
Michael UderDepartment of Radiology, University Hospital Erlangen, 91054 Erlangen, Germany.
Oliver RompelDepartment of Radiology, University Hospital Erlangen, 91054 Erlangen, Germany.
Universitätsklinikum Erlangen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Low-dose dual-source computed tomography (DSCT) protocols for the evaluation of lung diseases in children and adolescents are of importance since this age group is particularly prone to radiation damage. The aim of this study was to evaluate image quality of low-dose DSCT of the lung and to assess the potential of radiation dose reduction compared to digital radiographs (DR). Three groups, each consisting of 19 patients, were examined with different DSCT protocols using tin prefiltration (Sn96/64/32 ref. mAs at 100 kV). Different strengths of iterative reconstruction were applied (ADMIRE 2/3/4). DSCT groups were compared to 19 matched patients examined with posterior-anterior DR. Diagnostic confidence, detectability of anatomical structures and small lung lesions were evaluated on a 4-point Likert scale (LS 1 = unacceptable, 4 = fully acceptable; a value ≥ 3 was considered acceptable). Effective dose (ED) was 31-/21-/9-fold higher in Sn96/Sn64/Sn32 compared to DR. Diagnostic confidence was sufficient in Sn96/Sn64 (LS 3.4/3.2), reduced in Sn32 (LS 2.7) and the worst in DR (LS 2.4). In DSCT, detectability of small anatomical structures was always superior to DR (

Indexed as

DSCTlow-doselungpediatrictin filtration

Identifiers

PMID33578643
PMCPMC7916398
OpenAlexW3126256314

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked