Trial reportThe Lancet. Child & adolescent health2021
Real-time continuous glucose monitoring in preterm infants (REACT): an international, open-label, randomised controlled trial.
Trial report in The Lancet. Child & adolescent health, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 42 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
42 citing papers in PubMed, 3 syntheses or guidelines pooled it, 72 citations in OpenAlex.
- Effects of Continuous Versus Intermittent Glucose Monitoring in Intensive Care Unit Patients: A Systematic Review With Meta-Analysis.Acta anaesthesiologica Scandinavica · 2026Pooled it
- Continuous glucose monitoring for the prevention of morbidity and mortality in preterm infants.The Cochrane database of systematic reviews · 2021Pooled it
- Association between neonatal hyperglycemia and retinopathy of prematurity: a meta-analysis.European journal of pediatrics · 2021Pooled it
- Cerebral fuels within the first week of life in very preterm infants: a cohort study.Archives of disease in childhood. Fetal and neonatal edition · 2026Trial
- Composite Metric of Glycemic Control Q-Score Is Elevated in Pediatric and Adolescent/Young Adult Hematopoietic Stem Cell Transplant Recipients.Diabetes technology & therapeutics · 2023Trial
- How accurate is accurate enough? Point-of-care glucose measurement in the newborn-and why accuracy is only part of the problem.Pediatric research · 2026Article
- Association between elevated blood glucose level and brain injuries (IVH/WMI) in preterm infants.BMC pediatrics · 2026Article
- Neonatal blood glucose monitoring using glucose estimation by phase delay between oxy- and deoxyhemoglobin.Pediatric research · 2026Article
- Current Practices in Hyperglycemia Management in Neonatal Encephalopathy: A Treatment of Hyperglycemia in Neonatal Encephalopathy (THiNE) Consortium Study.American journal of perinatology · 2026Article
- Permanent Neonatal Diabetes with High Insulin Requirements due to a New Variant in theJournal of clinical research in pediatric endocrinology · 2026Article
- Neurobehavioral outcomes at 12 months in very preterm infants monitored with continuous glucose monitoring at birth compared with full-term infants.Scientific reports · 2026Article
- Evaluation of a subcutaneous continuous glucose monitoring system in critically ill neonatal foals.Journal of veterinary internal medicine · 2026Article
- The neonatal continuous glucose monitoring paradox: why at-risk infants still lack access to a transformative technology-A call for needs-led innovation.Frontiers in medicine · 2026Article
- Case Report: Subcutaneous sensor-augmented insulin pump therapy in a 510-g preterm infant with hyperglycemia.Frontiers in pediatrics · 2026Article
- Task-free functional connectivity changes before and after hyper- and hypoglycemia in very preterm neonates.Neurophotonics · 2026Article
- Glycemic variability and reference percentiles in very low birth weight preterm infants using continuous glucose monitoring.PloS one · 2026Observational
- Association of continuous glucose monitoring with in-hospital adverse outcomes among critically ill patients: a real-world propensity score-matched study.Frontiers in endocrinology · 2026Article
- Neurophysiological changes associated with dysglycemia in term neonates with neonatal encephalopathy.Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology · 2025Article
- Association of hyperglycemia in extremely preterm infants with neurodevelopmental outcomes at 18 months of corrected age.Journal of perinatology : official journal of the California Perinatal Association · 2025Article
- Investigating brain haemodynamics during hypoglycaemia in very preterm neonates using diffuse optical tomography.medRxiv : the preprint server for health sciences · 2025Article
Corrections and comments
- Commented on by
- Commented on by
- Commented on by
- Commented on by
Authors and funding
13 authors at 10 institutions in 3 countries.
Funding
Abstract
backgroundHyperglycaemia and hypoglycaemia are common in preterm infants and have been associated with increased risk of mortality and morbidity. Interventions to reduce risk associated with these exposures are particularly challenging due to the infrequent measurement of blood glucose concentrations, with the potential of causing more harm instead of improving outcomes for these infants. Continuous glucose monitoring (CGM) is widely used in adults and children with diabetes to improve glucose control, but has not been approved for use in neonates. The REACT trial aimed to evaluate the efficacy and safety of CGM in preterm infants requiring intensive care.
methodsThis international, open-label, randomised controlled trial was done in 13 neonatal intensive care units in the UK, Spain, and the Netherlands. Infants were included if they were within 24 h of birth, had a birthweight of 1200 g or less, had a gestational age up to 33 weeks plus 6 days, and had parental written informed consent. Infants were randomly assigned (1:1) to real-time CGM or standard care (with masked CGM for comparison) using a central web randomisation system, stratified by recruiting centre and gestational age (<26 or ≥26 weeks). The primary efficacy outcome was the proportion of time sensor glucose concentration was 2·6-10 mmol/L for the first week of life. Safety outcomes related to hypoglycaemia (glucose concentrations <2·6 mmol/L) in the first 7 days of life. All outcomes were assessed on the basis of intention to treat in the full analysis set with available data. The study is registered with the International Standard Randomised Control Trials Registry, ISRCTN12793535.
findingsBetween July 4, 2016, and Jan 27, 2019, 182 infants were enrolled, 180 of whom were randomly assigned (85 to real-time CGM, 95 to standard care). 70 infants in the real-time CGM intervention group and 85 in the standard care group had CGM data and were included in the primary analysis. Compared with infants in the standard care group, infants managed using CGM had more time in the 2·6-10 mmol/L glucose concentration target range (mean proportion of time 84% [SD 22] vs 94% [11]; adjusted mean difference 8·9% [95% CI 3·4-14·4]), equivalent to 13 h (95% CI 5-21). More infants in the standard care group were exposed to at least one episode of sensor glucose concentration of less than 2·6 mmol/L for more than 1 h than those in the intervention group (13 [15%] of 85 vs four [6%] of 70). There were no serious adverse events related to the use of the device or episodes of infection.
interpretationReal-time CGM can reduce exposure to prolonged or severe hyperglycaemia and hypoglycaemia. Further studies using CGM are required to determine optimal glucose targets, strategies to obtain them, and the potential effect on long-term health outcomes.
fundingNational Institute for Health Research Efficacy and Mechanisms Evaluation Programme.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.