Evidence map›Paper›PMID 33576378›Full record

ArticleEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology2021

Similar outcomes with manual contact force ablation catheters and traditional catheters in the treatment of outflow tract premature ventricular complexes.

Pál Ábrahám, Mercédesz Ambrus, Szilvia Herczeg, Nándor Szegedi, Klaudia Vivien Nagy, Zoltán Salló, István Osztheimer, Gábor Széplaki, Tamás Tahin, Béla Merkely and 1 more

Open access · bronzeAbstract read
In one paragraph

Article in Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.2field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 11 citations in OpenAlex.

  1. Combining contact force and local impedance to treat idiopathic premature ventricular contractions from the outflow tracts: impact of ablation strategy on outcomes.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2023
    Trial
  2. Article
  3. Article
  4. Twenty-five years of catheter ablation of ventricular tachycardia: a look back and a look forward.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023
    Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 1 institution in 1 country.

Pál ÁbrahámDepartment of Cardiology, Semmelweis University Heart and Vascular Centre, Városmajor Street 68, H-1122 Budapest, Hungary.
Mercédesz AmbrusDepartment of Cardiology, Semmelweis University Heart and Vascular Centre, Városmajor Street 68, H-1122 Budapest, Hungary.
Szilvia HerczegDepartment of Cardiology, Semmelweis University Heart and Vascular Centre, Városmajor Street 68, H-1122 Budapest, Hungary.
Nándor SzegediDepartment of Cardiology, Semmelweis University Heart and Vascular Centre, Városmajor Street 68, H-1122 Budapest, Hungary.
Klaudia Vivien NagyDepartment of Cardiology, Semmelweis University Heart and Vascular Centre, Városmajor Street 68, H-1122 Budapest, Hungary.
Zoltán SallóDepartment of Cardiology, Semmelweis University Heart and Vascular Centre, Városmajor Street 68, H-1122 Budapest, Hungary.
István OsztheimerDepartment of Cardiology, Semmelweis University Heart and Vascular Centre, Városmajor Street 68, H-1122 Budapest, Hungary.
Gábor SzéplakiDepartment of Cardiology, Semmelweis University Heart and Vascular Centre, Városmajor Street 68, H-1122 Budapest, Hungary.
Tamás TahinDepartment of Cardiology, Semmelweis University Heart and Vascular Centre, Városmajor Street 68, H-1122 Budapest, Hungary.
Béla MerkelyDepartment of Cardiology, Semmelweis University Heart and Vascular Centre, Városmajor Street 68, H-1122 Budapest, Hungary.
László GellérDepartment of Cardiology, Semmelweis University Heart and Vascular Centre, Városmajor Street 68, H-1122 Budapest, Hungary.
Semmelweis University · HU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsUnlike in atrial fibrillation ablation, there is a lack of appropriately sized and properly designed studies regarding outflow tract (OT) premature ventricular complex (PVC) ablation outcomes with contact force sensing (CFS) catheters. We aimed to compare the acute success-, complication-, and long-term recurrence rates of manual CFS catheters with traditional irrigated catheters (T) in OT PVC ablation. METHODS AND

resultsSingle-centre, propensity-matched data of 75-75 patients ablated for right-sided OT (RVOT) or left-sided OT (LVOT) PVCs in 2015-17 with CFS or T catheters were compared. Acute success rate, peri-procedural complications, post-procedural daily PVC burden, and long-term recurrence rates were compared on intention-to-treat basis. Acute success rate equalled 80% in both groups, with no difference in force values in the CFS group comparing successful or failed cases [12.0 (8.75-17.0) vs. 16.0 (10.25-22.25) g, P = 0.21]. There were three cases of pseudo-aneurysm and one cardiac tamponade. PVC burden fell significantly from baseline 22 (15-30)% to 2 (0-10)% (P < 0.0001), with no difference between catheter types [CFS: 1 (0-7)% vs. T: 4 (1-12) %; P = 0.21]. There was no significant difference in recurrence-free survival of CFS and T catheters (58 vs. 59%, P = 0.29) during 12 months of follow-up, respectively. Recurrence in the CFS group did not differ either by the force exerted below or above the median value of 12 g (P = 0.66).

conclusionBoth types of catheters can effectively reduce OT PVC burden with minimal serious complication rates. Ablation with CFS or T catheters gives similar acute- and long-term results.

Indexed as

Atrial FibrillationCatheter AblationVentricular Premature ComplexesCathetersHumansTreatment OutcomeCatheter ablationContact forceFollow-upOutflow tractPremature ventricular complexes

Identifiers

PMID33576378
PMCPMC8025084
OpenAlexW3126976554

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.