Evidence map›Paper›PMID 33575863›Full record

ArticleThe international journal of cardiovascular imaging2021

A comparison of 8 and 16 frames gated SPECT imaging for determination of left ventricular volumes and ejection fraction: effects of gender and myocardial counts.

Mahdi Mazinani, Mohammad Ali Tajik-Mansoury, Mahsa Sabour, Majid Jadidi

Abstract read
PubMed Publisher
In one paragraph

Article in The international journal of cardiovascular imaging, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Enhanced accuracy of cardiacEuropean journal of nuclear medicine and molecular imaging · 2026
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mahdi MazinaniDepartment of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran.ORCID http://orcid.org/0000-0002-3015-4532
Mohammad Ali Tajik-MansouryDepartment of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran. m_tajik@semums.ac.ir.ORCID http://orcid.org/0000-0002-9540-2672
Mahsa SabourRaaheaseman Center of Nuclear Medicine, Semnan University of Medical Science, Semnan, Iran.
Majid JadidiDepartment of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In myocardial gated SPECT imaging each cardiac cycle is divided into 8 or 16 temporal frames and the cause of the difference between 8 and 16 frames is not specified exactly. The aim of this study was to investigate the effect of myocardial detector counts and gender on the difference between 8 and 16 frames and also to compare the LVEF obtained by 8 and 16 frames with echocardiography. The study population included 84 patients who underwent gated SPECT imaging. Left ventricular parameters were assessed on 8 and 16 frames gated SPECT. LVEF was also measured with two-dimensional echocardiography within 5-10 days after gated SPECT imaging. There was a good correlation between 8 and 16 frames for calculation of LVEF (p = 0.00, r = 0.860), EDV (p = 0.00, r = 0.965) and ESV (p = 0.00, r = 0.956) in all patients. But the difference between 8 and 16 frames for calculation of LVEF (p = 0.00), EDV (p = 0.014) and ESV (p = 0.00) was statistically significant. This difference was assessed separately in females, males, patients with high photon counts and patients with low photon counts and in all subgroups was statistically significant difference in the estimation of LVEF and ESV (p < 0.05) but no significant difference in the estimation of EDV (p > 0.05). Echocardiography resulted in smaller LVEF as compared to 8 and 16 frames gated SPECT studies and there was a significant difference between the two methods (p = 0.00). The myocardial detector counts and gender have no effect on the difference between 8 and 16 frames methods and the LVEF on echocardiography is smaller than the gated SPECT, but the 8-frame is closer to echocardiography.

Indexed as

Gated Blood-Pool ImagingVentricular Dysfunction, LeftFemaleHumansMalePredictive Value of TestsReproducibility of ResultsStroke VolumeTomography, Emission-Computed, Single-PhotonTomography, X-Ray Computed8 and 16 frames gated SPECTEchocardiographyEjection fractionLV volumes

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.