Evidence map›Paper›PMID 33574637›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2020

X-ray luminescence imaging for small animals.

Michael C Lun, Wenxiang Cong, Md Arifuzzaman, Meenakshi Ranasinghe, Sriparna Bhattacharya, Jeffery Anker, Ge Wang, Changqing Li

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. High-resolution x-ray luminescence computed tomography.Proceedings of SPIE--the International Society for Optical Engineering · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Michael C LunDepartment of Bioengineering, University of California, Merced, Merced, CA 95343, USA.
Wenxiang CongDepartment of Biomedical Engineering, Biomedical Imaging Center, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY 12180, USA.
Md ArifuzzamanDepartment of Chemistry, Clemson University, Clemson, SC 29634, USA.
Meenakshi RanasingheDepartment of Chemistry, Clemson University, Clemson, SC 29634, USA.
Sriparna BhattacharyaClemson Nanomaterials Institute, Department of Physics & Astronomy, Clemson University, Clemson, SC 29634, USA.
Jeffery AnkerDepartment of Chemistry, Clemson University, Clemson, SC 29634, USA.
Ge WangDepartment of Biomedical Engineering, Biomedical Imaging Center, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY 12180, USA.
Changqing LiDepartment of Bioengineering, University of California, Merced, Merced, CA 95343, USA.

Funding

Life time imaging with pulsed x-ray based x-ray luminescence computed tomographyR01EB026646 · NIBIB · UNIVERSITY OF CALIFORNIA, MERCED · PI LI, CHANGQING · 2018 to 2021
$2.6M
NIBIB NIH HHS R01 EB026646
6 · The paper itself

Abstract

X-ray luminescence imaging emerged for about a decade and combines both the high spatial resolution of x-ray imaging with the high measurement sensitivity of optical imaging, which could result in a great molecular imaging tool for small animals. So far, there are two types of x-ray luminescence computed tomography (XLCT) imaging. One uses a pencil beam x-ray for high spatial resolution at a cost of longer measurement time. The other uses cone beam x-ray to cover the whole mouse to obtain XLCT images at a very short time but with a compromised spatial resolution. Here we review these two methods in this paper and highlight the synthesized nanophosphors by different research groups. We are building a focused x-ray luminescence tomography (FXLT) imaging system, developing a machine-learning based FXLT reconstruction algorithm, and synthesizing nanophosphors with different emission wavelengths. In this paper, we will report our current progress from these three aspects. Briefly, we mount all main components, including the focused x-ray tube, the fiber detector, and the x-ray tube and x-ray detector for a microCT system, on a rotary which is a heavy-duty ring track. A microCT scan will be performed before FXLT scan. For a FXLT scan, we will have four PMTs to measure four fiber detectors at two different wavelengths simultaneously for each linear scan position. We expect the spatial resolution of the FXLT imaging will be around 100 micrometers and a limit of detection of approximately 2 μg/mL (for Gd

Indexed as

mice imagingoptical imagingoptical tomographytomographic imagingx-ray imagingx-ray luminescence computed tomography

Identifiers

PMID33574637
PMCPMC7875188

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.