Evidence map›Paper›PMID 33572552›Full record

ArticleMolecules (Basel, Switzerland)2021

Development of an Interdigitated Electrode-Based Disposable Enzyme Sensor Strip for Glycated Albumin Measurement.

Mika Hatada, Noya Loew, Junko Okuda-Shimazaki, Mukund Khanwalker, Wakako Tsugawa, Ashok Mulchandani, Koji Sode

Open access · goldAbstract read
In one paragraph

Article in Molecules (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Review
  3. Type 1Micromachines · 2023
    Review
  4. Review
  5. Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Mika HatadaJoint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC 27599, USA.
Noya LoewJoint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC 27599, USA.
Junko Okuda-ShimazakiJoint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC 27599, USA.
Mukund KhanwalkerJoint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC 27599, USA.
Wakako TsugawaDepartment of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo 184-8588, Japan.ORCID 0000-0001-6299-5267
Ashok MulchandaniDepartment of Chemical and Environmental Engineering, University of California, Riverside, CA 92521, USA.ORCID 0000-0002-2831-4154
Koji SodeJoint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC 27599, USA.
University of North Carolina at Chapel Hill · USTokyo University of Agriculture and Technology · JPUniversity of California, Riverside · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Glycated albumin (GA) is an important glycemic control marker for diabetes mellitus. This study aimed to develop a highly sensitive disposable enzyme sensor strip for GA measurement by using an interdigitated electrode (IDE) as an electrode platform. The superior characteristics of IDE were demonstrated using one microelectrode of the IDE pair as the working electrode (WE) and the other as the counter electrode, and by measuring ferrocyanide/ferricyanide redox couple. The oxidation current was immediately reached at the steady state when the oxidation potential was applied to the WE. Then, an IDE enzyme sensor strip for GA measurement was prepared. The measurement of fructosyl lysine, the protease digestion product of GA, exhibited a high, steady current immediately after potential application, revealing the highly reproducible measurement. The sensitivity (2.8 nA µM

Indexed as

Disposable EquipmentBiosensing TechniquesElectrodesEnzymesGlycated Serum AlbuminGlycation End Products, AdvancedReproducibility of ResultsSerum AlbuminEnzymesGlycated Serum AlbuminGlycation End Products, AdvancedSerum Albumindiabetes mellitusdisposable enzyme sensorfructosyl amino acid oxidaseglycated albumininterdigitated electrodepoint of care testing

Identifiers

PMID33572552
PMCPMC7866809
OpenAlexW3128478654

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.