Evidence map›Paper›PMID 33570699›Full record

Trial reportKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2022

Patient-specific instruments do not show advantage over conventional instruments in unicompartmental knee arthroplasty at 2 year follow-up: a prospective, two-centre, randomised, double-blind, controlled trial.

Alexandra M Leenders, Nanne P Kort, Koen L M Koenraadt, Rutger C I van Geenen, Jasper Most, Bart Kerens, Bert Boonen, Martijn G M Schotanus

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.3field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 8 citations in OpenAlex.

  1. Trial
  2. Article
  3. Review
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 6 institutions in 3 countries.

Alexandra M LeendersDepartment of Orthopaedics, Zuyderland Medical Centre, Dr. H. van der Hoffplein 1, 6162 BG, Sittard-Geleen, The Netherlands. alexandraleenders@hotmail.com.ORCID http://orcid.org/0000-0003-0852-9294
Nanne P KortCortoClinics, Steeg 6E, 5482 WN, Schijndel, The Netherlands.
Koen L M KoenraadtDepartment of Orthopaedics, Amphia Hospital, Molengracht 21, 4814 CK, Breda, The Netherlands.
Rutger C I van GeenenDepartment of Orthopaedics, Amphia Hospital, Molengracht 21, 4814 CK, Breda, The Netherlands.
Jasper MostDepartment of Orthopaedics, Zuyderland Medical Centre, Dr. H. van der Hoffplein 1, 6162 BG, Sittard-Geleen, The Netherlands.
Bart KerensDepartment of Orthopaedics, AZ Sint-Maarten, Liersesteenweg 435, 2800, Mechelen, Belgium.
Bert BoonenDepartment of Orthopaedics, Zuyderland Medical Centre, Dr. H. van der Hoffplein 1, 6162 BG, Sittard-Geleen, The Netherlands.
Martijn G M SchotanusDepartment of Orthopaedics, Zuyderland Medical Centre, Dr. H. van der Hoffplein 1, 6162 BG, Sittard-Geleen, The Netherlands.
Amphia Ziekenhuis · NLZuyderland Medisch Centrum · NLAZ Sint-Lucas · BEMaastricht University Medical Centre · NLTata Steel (Netherlands) · NLVieCuri Medisch Centrum · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe aim of this two-centre RCT was to compare pre- and post-operative radiological, clinical and functional outcomes between patient-specific instrumentation (PSI) and conventional instrumented (CI) unicompartmental knee arthroplasty (UKA). It was hypothesised that both alignment methods would have comparable post-operative radiological, clinical and functional outcomes.

methodsOne hundred and twenty patients were included, and randomly allocated to the PSI or the CI group. Outcome measures were peri-operative outcomes (operation time, length of hospital stay and intra-operative changes of implant size) and post-operative radiological outcomes including the alignment of the tibial and femoral component in the sagittal and frontal plane and the hip-knee-ankle-axis (HKA-axis), rate of adverse events (AEs) and patient-reported outcome measures (PROMs) pre-operatively and at 3, 12 and 24 months post-operatively.

resultsThere was a statistically significant difference (p < 0.05) in alignment of the femoral component in the frontal plane in favour of the CI method. No statistically significant differences were found for the peri-operative data or in the functional outcome at 2-year follow-up. In the PSI group, the approved implant size of the femoral component was correct in 98.2% of the cases and the tibial component was correct in 60.7% of the cases. There was a comparable rate of AEs: 5.1% in the CI and 5.4% in the PSI group.

conclusionThe PSI method did not show an advantage over CI in regard of positioning of the components, nor did it show an improvement in clinical or functional outcome. We conclude that the possible advantages of PSI do not outweigh the costs of the MRI scan and the manufacturing of the PSI. LEVEL OF EVIDENCE: Randomised controlled trial, level I.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeSurgery, Computer-AssistedHumansKnee JointProspective StudiesAlignmentArthroplastyKneeKnee arthroplastyMRIPatient-specific instrumentationRadiographyReplacementUnicompartmental knee arthroplasty

Identifiers

PMID33570699
OpenAlexW3127838501

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.