Evidence map›Paper›PMID 33568708›Full record

ArticleScientific reports2021

PHAIR: a biosensor for pH measurement in air-liquid interface cell culture.

Mohammadhossein Dabaghi, Neda Saraei, Gang Xu, Abiram Chandiramohan, Jonas Yeung, Jenny P Nguyen, Milica Vukmirovic, Ponnambalam Ravi Selvaganapathy, Jeremy A Hirota

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.6field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Mohammadhossein DabaghiFirestone Institute for Respiratory Health-Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, L8N 4A6, Canada.
Neda SaraeiFirestone Institute for Respiratory Health-Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, L8N 4A6, Canada.
Gang XuFirestone Institute for Respiratory Health-Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, L8N 4A6, Canada.
Abiram ChandiramohanFirestone Institute for Respiratory Health-Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, L8N 4A6, Canada.
Jonas YeungDepartment of Mechanical Engineering, McMaster University, Hamilton, ON, L8S 4L7, Canada.
Jenny P NguyenFirestone Institute for Respiratory Health-Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, L8N 4A6, Canada.
Milica VukmirovicFirestone Institute for Respiratory Health-Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, L8N 4A6, Canada.
Ponnambalam Ravi SelvaganapathyDepartment of Mechanical Engineering, McMaster University, Hamilton, ON, L8S 4L7, Canada.
Jeremy A HirotaFirestone Institute for Respiratory Health-Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON, L8N 4A6, Canada. hirotaja@mcmaster.ca.
McMaster University · CAMcMaster University Medical Centre · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In many biological systems, pH can be used as a parameter to understand and study cell dynamics. However, measuring pH in live cell culture is limited by the sensor ion specificity, proximity to the cell surface, and scalability. Commercially available pH sensors are difficult to integrate into a small-scale cell culture system due to their size and are not cost-effective for disposable use. We made PHAIR-a new pH sensor that uses a micro-wire format to measure pH in vitro human airway cell culture. Tungsten micro-wires were used as the working electrodes, and silver micro-wires with a silver/silver chloride coating were used as a pseudo reference electrode. pH sensitivity, in a wide and narrow range, and stability of these sensors were tested in common standard buffer solutions as well as in culture media of human airway epithelial cells grown at the air-liquid interface in a 24 well cell culture plate. When measuring the pH of cells grown under basal and challenge conditions using PHAIR, cell viability and cytokine responses were not affected. Our results confirm that micro-wire-based sensors have the capacity for miniaturization and detection of diverse ions while maintaining sensitivity. This suggests the broad application of PHAIR in various biological experimental settings.

Indexed as

Biosensing TechniquesCell Culture TechniquesCell LineCell SurvivalCulture MediaCytokinesElectrochemical TechniquesHumansHydrogen-Ion ConcentrationMicroelectrodesMiniaturizationRespiratory MucosaSilver CompoundsTungstenCulture MediaCytokinessilver chlorideSilver CompoundsTungsten

Identifiers

PMID33568708
PMCPMC7875988
OpenAlexW3127897726

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.