Evidence map›Paper›PMID 33566856›Full record

ArticlePloS one2021

A three-dimensional finite element analysis on the effects of implant materials and designs on periprosthetic tibial bone resorption.

Hyung Jun Park, Tae Soo Bae, Seung-Baik Kang, Hyeong Ho Baek, Moon Jong Chang, Chong Bum Chang

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Hyung Jun ParkDepartment of Orthopedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, Seoul, South Korea.
Tae Soo BaeDepartment of Biomedical Engineering (BME), Jungwon University, Chungcheongbuk-do, South Korea.
Seung-Baik KangDepartment of Orthopedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, Seoul, South Korea.ORCID 0000-0002-1184-4482
Hyeong Ho BaekDepartment of Biomedical Engineering (BME), Jungwon University, Chungcheongbuk-do, South Korea.ORCID 0000-0002-6041-0357
Moon Jong ChangDepartment of Orthopedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, Seoul, South Korea.
Chong Bum ChangDepartment of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam, South Korea.
Seoul National University · KRJungwon University · KRSeoul National University Bundang Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionImplant material is a more important factor for periprosthetic tibial bone resorption than implant design after total knee arthroplasty (TKA). The virtual perturbation study was planned to perform using single case of proximal tibia model. We determined whether the implant materials' stiffness affects the degree of periprosthetic tibial bone resorption, and whether the effect of material change with the same implant design differed according to the proximal tibial plateau areas. MATERIALS AND

methodsThis three-dimensional finite element analysis included two cobalt-chromium (CoCr) and two titanium (Ti) tibial implants with different designs. They were implanted into the proximal tibial model reconstructed using extracted images from computed tomography. The degree of bone resorption or formation was measured using the strain energy density after applying axial load. The same analysis was performed after exchanging the materials while maintaining the design of each implant.

resultsThe degree of periprosthetic tibial bone resorption was not determined by the type of implant materials alone. When the implant materials were changed from Ti to CoCr, the bone resorption in the medial compartment increased and vice versa. The effect of material composition's change on anterior and posterior areas varied accordingly.

conclusionsAlthough the degree of bone resorption was associated with implant materials, it differed depending on the design of each implant. The effect on the degree of bone resorption according to the materials after TKA should be evaluated while concomitantly considering design.

Indexed as

Bone ResorptionProstheses and ImplantsProsthesis DesignTibiaBone-Implant InterfaceChromium AlloysFinite Element AnalysisHumansTitaniumChromium AlloysTitanium

Identifiers

PMID33566856
PMCPMC7875353
OpenAlexW3127378192

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.