An Innovative Wearable Device For Monitoring Continuous Body Surface Temperature (HEARThermo): Instrument Validation Study.

Chun-Yin Yeh, Yi-Ting Chung, Kun-Ta Chuang, Yu-Chen Shu, Hung-Yu Kao, Po-Lin Chen, Wen-Chien Ko, Nai-Ying Ko

Open access · goldAbstract read
In one paragraph

Article in JMIR mHealth and uHealth, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 10 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Chun-Yin YehDepartment of Computer Science and Information Engineering, National Cheng Kung University, Tainan, Taiwan.ORCID 0000-0002-0164-3468
Yi-Ting ChungDepartment of Nursing, National Cheng Kung University, Tainan, Taiwan.ORCID 0000-0001-7658-9542
Kun-Ta ChuangDepartment of Computer Science and Information Engineering, National Cheng Kung University, Tainan, Taiwan.ORCID 0000-0002-3914-8550
Yu-Chen ShuDepartment of Mathematics, National Cheng Kung University, Tainan, Taiwan.ORCID 0000-0002-6450-7076
Hung-Yu KaoDepartment of Computer Science and Information Engineering, National Cheng Kung University, Tainan, Taiwan.ORCID 0000-0002-8890-8544
Po-Lin ChenDepartment of Medicine, National Cheng Kung University, Tainan, Taiwan.ORCID 0000-0002-4015-1052
Wen-Chien KoDepartment of Medicine, National Cheng Kung University, Tainan, Taiwan.ORCID 0000-0001-7497-149X
Nai-Ying KoDepartment of Nursing, National Cheng Kung University, Tainan, Taiwan.ORCID 0000-0002-3007-2537
National Cheng Kung University · TWNational Cheng Kung University Hospital · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundVariations in body temperature are highly informative during an illness. To date, there are not many adequate studies that have investigated the feasibility of a wearable wrist device for the continuous monitoring of body surface temperatures in humans.

objectiveThe objective of this study was to validate the performance of HEARThermo, an innovative wearable device, which was developed to continuously monitor the body surface temperature in humans.

methodsWe implemented a multi-method research design in this study, which included 2 validation studies-one in the laboratory and one with human subjects. In validation study I, we evaluated the test-retest reliability of HEARThermo in the laboratory to measure the temperature and to correct the values recorded by each HEARThermo by using linear regression models. We conducted validation study II on human subjects who wore HEARThermo for the measurement of their body surface temperatures. Additionally, we compared the HEARThermo temperature recordings with those recorded by the infrared skin thermometer simultaneously. We used intraclass correlation coefficients (ICCs) and Bland-Altman plots to analyze the criterion validity and agreement between the 2 measurement tools.

resultsA total of 66 participants (age range, 10-77 years) were recruited, and 152,881 completed data were analyzed in this study. The 2 validation studies in the laboratory and on human skin indicated that HEARThermo showed a good test-retest reliability (ICC 0.96-0.98) and adequate criterion validity with the infrared skin thermometer at room temperatures of 20°C-27.9°C (ICC 0.72, P<.001). The corrected measurement bias averaged -0.02°C, which was calibrated using a water bath ranging in temperature from 16°C to 40°C. The values of each HEARThermo improved by the regression models were not significantly different from the temperature of the water bath (P=.19). Bland-Altman plots showed no visualized systematic bias. HEARThermo had a bias of 1.51°C with a 95% limit of agreement between -1.34°C and 4.35°C.

conclusionsThe findings of our study show the validation of HEARThermo for the continuous monitoring of body surface temperatures in humans.

Indexed as

Body TemperatureWearable Electronic DevicesAdolescentAdultAgedChildHumansMiddle AgedMonitoring, PhysiologicReproducibility of ResultsTemperatureYoung Adultbody surface temperaturecontinuous monitoringvalidationwearable device

Identifiers

PMID33565990
PMCPMC7904403
OpenAlexW3120687892

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.