ArticleDento maxillo facial radiology2021
Influence of size of field of view (FOV), position within the FOV, and scanning mode on the detection of root fracture and observer's perception of artifacts in CBCT images.
Article in Dento maxillo facial radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Reliability and agreement of CBCT-based alveolar bone assessments for follow-up studies on adolescent orthodontic patients using multiplanar reconstruction and various CBCT units.Progress in orthodontics · 2026Trial
- Optimizing CBCT acquisition for detecting non-displaced dentoalveolar fractures: effects of field of view and resolution mode.BMC oral health · 2026Article
- Ex Vivo Quantitative Evaluation of Beam Hardening Artifacts at Various Implant Locations in Cone-Beam Computed Tomography Using Metal Artifact Reduction and Noise Reduction Techniques.Diagnostics (Basel, Switzerland) · 2025Article
- Exploring Diagnostic Reliability of CBCT for Vertical Root Fractures: A Systematic Review and Meta-Analytical Approach.International journal of dentistry · 2025Review
- Filtered back projection vs. iterative reconstruction for CBCT: effects on image noise and processing time.Dento maxillo facial radiology · 2023Article
- The effects of different metal posts, cements, and exposure parameters on cone-beam computed tomography artifacts.Imaging science in dentistry · 2023Article
- [Strategies for the use of cone beam tomography in teeth with suspected root fracture. Report of case series].Revista cientifica odontologica (Universidad Cientifica del Sur)Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo assess the influence of field of view (FOV) size, scanning position within the FOV and scanning mode on the detection of root fracture and artifact perception.
methodsForty single-rooted premolars restored with NiCr and AgPd posts were divided into two groups: fractured and sound. All teeth were scanned using four CBCT scanning protocols varying FOV sizes (80 × 80 mm and 50 × 55 mm) and scanning modes (Standard and High Definition). The sample was positioned within the FOV in two pre-set positions (central and lateral) and in four positions established by the operator (quadrants). Detection of root fracture and artifact perception were assessed by two observers using 5-point and 4-point scales. Sensitivity, specificity, accuracy, and AUC values were calculated and compared by ANOVA two-way and Tukey's test. Chi-square and Fisher's exact test were used to assess artifact perception. The level of significance was set at p < 0.05.
resultsThe central position within the FOV presented higher sensitivity, specificity, accuracy, and AUC values and differed from the lateral position within the FOV for the studied metal posts (p<0.05). Quadrant 2 presented the best sensitivity, accuracy, and AUC values (p<0.05). The lateral position within the FOV, AgPd posts, quadrants 1 and 3 and protocols 1 (SM, 80 × 80) and 2 (HD, 80× 80) presented higher frequency of artifacts classified as "severe".
conclusionPositioning the object in the center or closer to the anterior periphery of the FOV while using a small FOV improved the detection of root fracture and decreased artifact perception.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.