Evidence map›Paper›PMID 33565135›Full record

ArticleMagnetic resonance in medicine2021

Minimum electric-field gradient coil design: Theoretical limits and practical guidelines.

Peter B Roemer, Brian K Rutt

Open access · hybridAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 21 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Peter B RoemerRoemer Consulting, Lutz, Florida, USA.
Brian K RuttDepartment of Radiology, Stanford University, Stanford, California, USA.ORCID 0000-0001-6516-0505
Stanford University · US

Funding

TRD4 - Ultrahigh Field Engineering and SafetyP41EB027061 · NIBIB · UNIVERSITY OF MINNESOTA · PI Gregory John Metzger · 2019 to 2026
$11.7M
Training and DisseminationP41EB015891 · NIBIB · STANFORD UNIVERSITY · PI GLOVER, GARY H · 2012 to 2019
$10.7M
Elementary Neuronal Ensembles to Whole Brain Networks: Ultrahigh Resolution Imaging of Function and Connectivity in Humans - SUPPLEMENTU01EB025144 · NIBIB · UNIVERSITY OF MINNESOTA · PI UGURBIL, KAMIL · 2017 to 2022
$9.7M
Accessing the Neuronal Scale: Designing the Next Generation of Compact Ultra High Field MRI Technology for Order-of-Magnitude Sensitivity Increase in Non-Invasive Human Brain MappingR01EB025131 · NIBIB · STANFORD UNIVERSITY · PI RUTT, BRIAN KEITH · 2017 to 2018
$989k
Next Generation 7T MRI Platform Upgrade with Parallel Transmit CapabilitiesS10RR026351 · NCRR · STANFORD UNIVERSITY · PI RUTT, BRIAN KEITH · 2011 to 2011
$600k
NCRR NIH HHS S10 RR026351NIBIB NIH HHS P41 EB015891NIBIB NIH HHS P41 EB027061NIBIB NIH HHS R01 EB025131NIBIB NIH HHS U01 EB025144
6 · The paper itself

Abstract

purposeTo develop new concepts for minimum electric-field (E-field) gradient design, and to define the extents to which E-field can be reduced in gradient design while maintaining a desired imaging performance.

methodsEfficient calculation of induced electric field in simplified patient models was integrated into gradient design software, allowing constraints to be placed on the peak E-field. Gradient coils confined to various build envelopes were designed with minimum E-fields subject to standard magnetic field constraints. We examined the characteristics of E-field-constrained gradients designed for imaging the head and body and the importance of asymmetry and concomitant fields in achieving these solutions.

resultsFor transverse gradients, symmetric solutions create high levels of E-fields in the shoulder region, while fully asymmetric solutions create high E-fields on the top of the head. Partially asymmetric solutions result in the lowest E-fields, balanced between shoulders and head and resulting in factors of 1.8 to 2.8 reduction in E-field for x-gradient and y-gradient coils, respectively, when compared with the symmetric designs of identical gradient distortion.

conclusionsWe introduce a generalized method for minimum E-field gradient design and define the theoretical limits of magnetic energy and peak E-field for gradient coils of arbitrary cylindrical geometry.

Indexed as

Magnetic FieldsMagnetic Resonance ImagingElectricityEquipment DesignHeadHumansasymmetric gradientE-fieldelectric fieldfolded gradientgradient coilhead gradientperipheral nerve stimulationPNS

Identifiers

PMID33565135
PMCPMC8049068
OpenAlexW3128828458

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.