Pressure Sensor System for Customized Scoliosis Braces.
Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 25 citations in OpenAlex.
- A hemispherical latitude-gradient sensor for closed-loop monitoring and management of scoliosis correction.Science advances · 2026Article
- A novel spinal orthosis with embedded shape memory alloy for adolescent idiopathic scoliosis.Biomedical engineering online · 2026Article
- Application of a Smart Orthosis in the Treatment of Idiopathic Scoliosis-A Pilot Case Study.Sensors (Basel, Switzerland) · 2026Article
- Smart Wheelchair and Sensor System for Tracking Performance and Accessibility in Urban Environments.Sensors (Basel, Switzerland) · 2026Article
- Brace Dose in Scoliosis: Measurement, Monitoring, and Clinical Decision-Making-A Narrative Review.Orthopedic research and reviews · 2026Review
- Article
- Wearable Devices in Scoliosis Treatment: A Scoping Review of Innovations and Challenges.Bioengineering (Basel, Switzerland) · 2025Review
- Mechanical and Thermo-Regulative Investigations on Additively Manufactured Backpack Pads.Polymers · 2025Article
- The Application of Integrated Force and Temperature Sensors to Enhance Orthotic Treatment Monitoring in Adolescent Idiopathic Scoliosis: A Pilot Study.Sensors (Basel, Switzerland) · 2025Article
- Improving Home-Based Scoliosis Therapy: Findings From a Web-Based Survey.JMIR rehabilitation and assistive technologies · 2023Article
- A Novel Force-Sensing Smart Textile: Inserting Silicone-Embedded FBG Sensors into a Knitted Undergarment.Sensors (Basel, Switzerland) · 2023Article
- Review
- Pressure Sensors for Measuring the Grip Pressure during Kendo Attacks: Assessment of Laterality and Evidence of the Five Phases of Attack.Sensors (Basel, Switzerland) · 2023Article
- TLSO with Graphene Sensors-An Application to Measurements of Corrective Forces in the Prototype of Intelligent Brace.Sensors (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Hard-shell thoracolumbar sacral orthoses (TLSOs) are used for treating idiopathic scoliosis, a deformation of the spine with a sideways curvature. The pressure required inside the TLSO for ideal corrective results remains unclear. Retrofitting TLSOs with commercially available pressure measurement systems is expensive and can only be performed in a laboratory. The aim of this study was to develop a cost-effective but accurate pressure sensor system for TLSOs. The sensor was built from a piezoresistive polymer, placed between two closed-cell foam liners, and evaluated with a material testing machine. Because foams are energy absorbers, the pressure-conductance curve was affected by hysteresis. The sensor was calibrated on a force plate with the transitions from loading to unloading used to establish the calibration curve. The root mean square error was 12% on average within the required pressure range of 0.01-0.13 MPa. The sensor reacted to the changing pressure during breathing and different activities when tested underneath a chest belt at different tensions. The peak pressure reached 0.135 MPa. The sensor was further tested inside the scoliosis brace during different activities. The measured pressure was 0.014-0.124 MPa. The results from this study enable cheaper and mobile systems to be used for clinical studies on the comfort and pressure of braces during daily activities.