Evidence map›Paper›PMID 33557770›Full record

ArticleBMC ophthalmology2021

Optimization of orbital retraction during endoscopic transorbital approach via quantitative measurement of the intraocular pressure - [SevEN 006].

Woohyun Kim, Ju Hyung Moon, Eui Hyun Kim, Chang-Ki Hong, Jisang Han, Je Beom Hong

Open access · goldAbstract read
In one paragraph

Article in BMC ophthalmology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
3.3field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 30 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Endoscopic transorbital decompression for traumatic superior orbital fissure syndrome: from cadaveric study to clinical application.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2024
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Woohyun KimDepartment of Neurosurgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Ju Hyung MoonDepartment of Neurosurgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Eui Hyun KimDepartment of Neurosurgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Chang-Ki HongDepartment of Neurosurgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Jisang HanDepartment of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea.
Je Beom HongDepartment of Neurosurgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, 29 Saemunan-ro, Jongno-gu, Seoul, 03181, Korea. jebeomhong@gmail.com.ORCID http://orcid.org/0000-0002-4812-565X
Yonsei University · KRKangbuk Samsung Hospital · KR

Funding

Yonsei University College of Medicine 6-2020-0224
6 · The paper itself

Abstract

backgroundIncreased use of the transorbital approach (TOA) warrants greater understanding of the risk of increased intraocular pressure (IOP) and intraorbital pressure (IORP) due to orbital compression. We aimed to investigate the changes in IOP and IORP in response to orbital retraction in TOA and establish a method for the continuous measurement of intraoperative IORP.

methodsWe assessed nine patients who underwent TOA surgery from January 2017 to December 2019, in addition to five cadavers. IORP and IOP were measured using a cannula needle monitor, tonometer, cuff manometer, and micro strain gauge monitor.

resultsIn all nine clinical cases and five cadavers, increased physical compression of the orbit increased the IOP and IORP in a curvilinear pattern. In clinical cases, when the orbit was compressed 1.5 cm from the lateral margin in the sagittal plane, the mean IOP and IORP were 25.4 ± 5.2 mmHg and 14 ± 9.2 mmH

conclusionWe measured IOP and IORP simultaneously during orbital compression to gain basic information on pressure changes. In clinical cases, the change in the IOP could be conveniently and noninvasively monitored using continuous IORP measurements.

Indexed as

GlaucomaIntraocular PressureEndoscopyHumansOrbitTonometry, OcularIntraocular pressureIntraorbital pressureOrbital compressionTransorbital approach

Identifiers

PMID33557770
PMCPMC7871604
OpenAlexW3118344339

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.