Evidence map›Paper›PMID 33552628›Full record

ArticleJournal of pharmaceutical analysis2021

Accurate and sensitive determination of hydroxychloroquine sulfate used on COVID-19 patients in human urine, serum and saliva samples by GC-MS.

Süleyman Bodur, Sezin Erarpat, Ömer Tahir Günkara, Sezgin Bakırdere

Open access · goldAbstract read
In one paragraph

Article in Journal of pharmaceutical analysis, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
4.0field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 30 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Süleyman BodurYıldız Technical University, Faculty of Art and Science, Department of Chemistry, 34210, Davutpasa, Esenler, Istanbul, Turkey.
Sezin ErarpatYıldız Technical University, Faculty of Art and Science, Department of Chemistry, 34210, Davutpasa, Esenler, Istanbul, Turkey.
Ömer Tahir GünkaraYıldız Technical University, Faculty of Art and Science, Department of Chemistry, 34210, Davutpasa, Esenler, Istanbul, Turkey.
Sezgin BakırdereYıldız Technical University, Faculty of Art and Science, Department of Chemistry, 34210, Davutpasa, Esenler, Istanbul, Turkey.
Yıldız Technical University · TRTurkish Academy of Sciences · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A rapid, accurate, and sensitive analytical method, ultrasonication-assisted spraying based fine droplet formation-liquid phase microextraction-gas chromatography-mass spectrometry (UA-SFDF-LPME-GC-MS), was proposed for the determination of trace amounts of hydroxychloroquine sulfate in human serum, urine, and saliva samples. To determine the best extraction strategy, several liquid and solid phase extraction methods were investigated for their efficiencies in isolation and preconcentration of hydroxychloroquine sulfate from biological matrices. The UA-SFDF-LPME method was determined to be the best extraction method as it was operationally simple and provided accurate results. Variables such as the extraction solvent, spraying number, sodium hydroxide concentration and volume, sample volume, mixing method, and mixing period were optimized for the proposed method using the one-variable-at-a-time approach. In addition, Tukey's method based on a post hoc comparison test was employed to evaluate the significant difference between the parameters inspected. After the optimization studies, the limit of detection (LOD) and limit of quantification (LOQ) were determined to be 0.7 and 2.4 μg/kg, respectively. The sensitivity of the GC-MS system based on the LOD was enhanced approximately 440-fold when the UA-SFDF-LPME method was employed. Spiking experiments were also conducted for the human serum, urine, and saliva samples to determine the applicability and accuracy of the proposed method. Recoveries for the human serum, urine, and saliva samples were found to be in the ranges of 93.9%-101.7%, 95.2%-105.0%, and 93.1%-102.3%, respectively. These results were satisfactory and indicated that the hydroxychloroquine sulfate level in the above biological samples could be analyzed using the proposed method.

Indexed as

Biological samplesDispersive solid phase extractionGC-MSHydroxychloroquine sulfateLiquid phase microextraction

Identifiers

PMID33552628
PMCPMC7847195
OpenAlexW3127831446

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.