Evidence map›Paper›PMID 33551527›Full record

ArticleMicroelectronic engineering2014

An integrated planar magnetic micropump.

Junhui Ni, Bin Wang, Stanley Chang, Qiao Lin

Abstract read
In one paragraph

Article in Microelectronic engineering, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Top-Down Fabricated Wood-Derived Pressure and Strain Sensors: A Review.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  2. A Mini-Patch Magnetic Insulin Pump for Enhanced Delivery Resolution and Accuracy.Advanced intelligent systems (Weinheim an der Bergstrasse, Germany) · 2026
    Article
  3. Review
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Junhui NiCollege of Mechanical Engineering, Taizhou University, Taizhou, Zhejiang, China.
Bin WangDepartment of Mechanical Engineering, Columbia University, New York, USA.
Stanley ChangDepartment of Ophthalmology, Columbia University, New York, USA.
Qiao LinDepartment of Mechanical Engineering, Columbia University, New York, USA.

Funding

Microfluidic Selection of Aptamers for Biological Purification ApplicationsR21RR025816 · NCRR · COLUMBIA UNIV NEW YORK MORNINGSIDE · PI LIN, QIAO · 2010 to 2011
$392k
NCRR NIH HHS R21 RR025816
6 · The paper itself

Abstract

This paper presents an integrated magnetic micropump that uses in-plane compliance-based check valves and a magnetically actuated membrane. The device, which allows for simple fabrication and system integration with other functional elements, consists of two functional layers both fabricated from poly(dimethylsiloxane) (PDMS). The upper PDMS layer provides a compliant membrane with an electroplated thin-film permalloy strip for actuation, while the lower PDMS layer incorporates microfluidic components including the microchannels, pump chamber, and a pair of check valves for flow regulation. The PDMS check valves, each having a compliant flap in contact with a stiff stopper to allow for unidirectional fluid flow with minimized leakage, are located at the inlet and outlet of the pump chamber, respectively. As such, the unidirectional flow at a controlled volumetric rate can be readily generated in accordance with the pumping actions. Systematic characterization of the micropump has been performed by studying the dependence of its pumping flow rate on the driving frequency of magnetic actuation, and the back pressure. Experimental results show that this micropump is capable of generating fluid flow of 0.15 μL/min at the frequency of 2 Hz, corresponding to a volume resolution of 1 nL per stroke, and working reliably against a maximum back-pressure of 550 Pa, demonstrating the potential application of this micropump for various integrated lab-on-a-chip systems.

Indexed as

Lab-on-a-chipMagnetic actuationMicropumpPDMS

Identifiers

PMID33551527
PMCPMC7861489

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.