Evidence map›Paper›PMID 33549392›Full record

ArticleChinese journal of traumatology = Zhonghua chuang shang za zhi2021

Treatment of irreducible femoral intertrochanteric fractures using a wire-guided device.

Kai-Bin Fang, Xiao-Cong Lin, Shao-Jian Shi, Zhang-Sheng Dai

Open access · diamondAbstract readComparative Study
In one paragraph

Article in Chinese journal of traumatology = Zhonghua chuang shang za zhi, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Kai-Bin FangDepartment of Orthopedic Surgery, Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian Province, China.
Xiao-Cong LinDepartment of Orthopedic Surgery, Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian Province, China.
Shao-Jian ShiDepartment of Orthopedic Surgery, Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian Province, China.
Zhang-Sheng DaiDepartment of Orthopedic Surgery, Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian Province, China. Electronic address: fjmufkb@foxmail.com.
Fujian Medical University · CNSecond Affiliated Hospital of Fujian Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTreatment of irreducible femoral intertrochanteric fractures often requires open reduction. However, the technique unavoidably causes patients to suffer greater trauma. As such, minimally invasive techniques should be employed to reduce the surgical-related trauma on these patients and maintain a stable reduction of the fractures. Herein, a minimally invasive wire introducer was designed and used for the treatment of femoral intertrochanteric fractures. The effectiveness of using a wire-guided device to treat irreducible femoral intertrochanteric fractures was evaluated.

methodsBetween 2013 and 2018, patients with femoral intertrochanteric fractures who were initially treated by intramedullary nail fixation but had difficult reduction using the traction beds were retrospectively reviewed. Decision for an additional surgery was based on the displacement of the fracture. The patients were then divided into two groups: those in the control group received an open reduction surgery while those in the observation group received a closed reduction surgery using a minimally invasive wire introducer to guide the wire that could assist in fracture reduction. The operation time, blood loss, visual analogue scale scores, angulation, reduction, neck-shaft angle, re-displacement, limb length discrepancy, and union time were then recorded and analyzed to determine the efficiency of the wire introducer technique. Categorical variables were analyzed by using Chi-square test, while continuous variables by independent t-test and the Mann-Whitney test accordingly.

resultsThere were 92 patients included in this study: 61 in the control group and 31 in the observation group. There were no significant differences in baseline demographic factors between the two groups. All surgeries were successful with no deaths within the perioperative period. The average follow-up time for the patients was 23.8 months. However, the observation group had a significantly shorter operation time, lower visual analogue scale score, less intraoperative bleeding, and shorter fracture healing time. There were no significant differences in the angulation, reduction, neck-shaft angle, and limb length discrepancy between the two groups.

conclusionThe minimally invasive wire guide achieved a similar effect to that of open reduction in the treatment of intertrochanteric fractures with difficult reduction. Moreover, the minimally invasive wire introducer is a good technology that accurately guides the wire during reduction. Indeed, it is an effective technique and achieves good clinical outcomes in restoration of irreducible femoral intertrochanteric fractures.

Indexed as

AgedBlood Loss, SurgicalBone WiresFemaleFracture Fixation, IntramedullaryHip FracturesHumansMaleMiddle AgedMinimally Invasive Surgical ProceduresOpen Fracture ReductionOperative TimeTreatment OutcomeBone wiresFemoral fracturesHip fracturesMinimally invasive surgical procedures

Identifiers

PMID33549392
PMCPMC8071721
OpenAlexW3121103422

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.