ArticleArchives of orthopaedic and trauma surgery2021
Evaluation of the accuracy of resected bone thickness based on patient-specific instrumentation during total knee arthroplasty.
Article in Archives of orthopaedic and trauma surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 7 citations in OpenAlex.
- Accuracy and Precision of Femoral and Tibial Bone Resections Using Manual Unrestricted Kinematic Alignment in Total Knee Arthroplasty: A Retrospective Digital Caliper Study.Journal of clinical medicine · 2026Article
- Femoral resection accuracy and precision in manual caliper-verified kinematic alignment total knee arthroplasty.Journal of experimental orthopaedics · 2025Article
- High accuracy of a new robotically assisted technique for total knee arthroplasty: an in vivo study.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Article
- Assistive technologies in knee arthroplasty: fashion or evolution? Rate of publications and national registries prove the Scott Parabola wrong.Archives of orthopaedic and trauma surgery · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIn total knee arthroplasty (TKA) using patient-specific instrumentation (PSI), the correlation between the preoperative surgical plan and intraoperative resection size is unclear. The aims of this study were to evaluate whether the computed tomography (CT)-based PSI surgical plan can be executed accurately and to determine the accuracy of bone resection in TKA using PSI.
methodsData of 45 consecutive knees undergoing TKA using CT-based PSI were retrospectively evaluated. The preoperative plan was prepared using three-dimensional CT acquisitions of the hip, knee, and ankle joints. Resected bone thicknesses of the femoral condyle of the distal medial, distal lateral, posterior medial, posterior lateral, and medial and lateral tibial plateaus were measured with a Vernier caliper intraoperatively. Then these respective measurements were compared with those in the preoperative CT-predicted bone resection surgical plan, and the measured thickness of resection was subtracted from the planned resection thickness. Errors were defined as: acceptable, ≤ 1.5 mm; borderline, 1.5-2.5 mm; and outliers, > 2.5 mm.
resultsOverall, 22 (48.9%) knees had no outliers. There were 20 (44.4%) and 3 (6.7%) knees in which only 1 and 2 resection planes were outliers, respectively. The posterior medial tibial plateau had the lowest proportion of acceptable cuts (44.4%). Posterior femoral resection including the medial and lateral condyles had more outliers (n = 18/90 cuts, 20.0%) (p < 0.001) than the tibial condyles (n = 3/90 cuts, 3.3%) and distal femoral cuts (n = 6/90 cuts, 6.7%). The posterior surface of the femur, where the incidence of outliers was higher, tended to have a higher proportion of undercuts than other surfaces of the femur (> 80%).
conclusionsPSI showed only fair-to-moderate accuracy. The cutting guide for the posterior femur was less accurate than that for the tibia and distal femur. Specific attention is required when cutting the posterior femur. The PSI design needs to be improved to reduce errors.